108 Program features
Programmable analog output
One programmable current output (0 … 20 mA) is available. Analog output signal can
be inverted, filtered and the maximum and minimum values can be adjusted. The
analog output signals can be proportional to motor speed, output frequency, output
current, motor torque, motor power, etc. The update cycle for the analog output is
2 ms.
It is also possible to write a value to an analog output through a serial communication
link.
Settings
Diagnostics
Parameter
Additional information
AO value selection and processing
AO in motor temperature measurement
Actual signal
Additional information
AO value
Fault
Incorrect AO signal scaling (