1-11
Errored-frame Event threshold : 10
Errored-frame-period Event period(in ms) : 1000
Errored-frame-period Event threshold : 1
Errored-frame-seconds Event period(in seconds) : 60
Errored-frame-seconds Event threshold : 1
According to the above output information, the detection period of errored frame events is 20 seconds,
the detection threshold is 10 seconds, and all the other parameters use the default values.
You can use the
display oam link-event
command to display the statistics about Ethernet OAM link
events and use the
display oam critical-event
command to display the Ethernet OAM configuration
information. For example:
# Display the statistics of Ethernet OAM critical link events on all the ports of Device A.
[DeviceA] display oam critical-event
Port : GigabitEthernet2/0/1
Link Status : Up
Event statistic :
-------------------------------------------------------------------------
Link Fault :0 Dying Gasp : 0 Critical Event : 0
According to the above output information, no critical link event occurred on the link between Device A
and Device B.
# Display Ethernet OAM link event statistics of the remote end of Device B.
[DeviceB] display oam link-event remote
Port :GigabitEthernet2/0/1
Link Status :Up
OAMRemoteErrFrameEvent : (ms = milliseconds)
---------------------------------------------------------------------
Event Time Stamp : 5789 Errored FrameWindow : 10(100ms)
Errored Frame Threshold : 1 Errored Frame : 3
Error Running Total : 35 Event Running Total : 17
The above information indicates that 35 errors occurred since Ethernet OAM is enabled on Device A, 17
of which are caused by error frames. The link is instable.
Summary of Contents for S7906E - Switch
Page 82: ...1 4 DeviceA interface tunnel 1 DeviceA Tunnel1 service loopback group 1...
Page 200: ...1 11 DeviceB display vlan dynamic No dynamic vlans exist...
Page 598: ...ii...
Page 1757: ...4 9...
Page 1770: ...6 4...
Page 2017: ...2 11 Figure 2 3 SFTP client interface...
Page 2238: ...1 16 DeviceA cfd linktrace service instance 1 mep 1001 target mep 4002...