1-17
To do…
Use the command…
Remarks
Configure the Hello timer and
Fail timer for the RRPP domain
timer hello-timer
hello-value
fail-timer fail-value
Required
By default, the Hello timer value
is 1 second and the Fail timer
value is 3 seconds.
z
The Fail timer value must be equal to or greater than three times the Hello timer value.
z
To avoid temporary loops when the primary ring fails in a dual-homed-ring network, ensure that the
difference between the Fail timer value on the master node of the subring and that on the master
node of the primary ring is greater than twice the Hello timer value of the master node of the
subring.
Configuring RRPP Fast Detection
The S7900E series Ethernet switches support RRPP fast detection only after SD or EB cards are
mounted in them.
Enabling Fast Detection
Perform this configuration on the master node, edge node, and assistant-edge node in the RRPP
domain to be configured.
Follow these steps to enable fast detection:
To do…
Use the command…
Remarks
Enter system view
system-view
—
Enter RRPP domain view
rrpp domain
domain-id
—
Enable fast detection
fast-detection enable
Required
Disabled by default
To configure fast detection on the master node of a subring, make sure that the edge node and
assistant-edge node of the subring supports fast detection. Otherwise, you are not recommended to
configure fast detection on the master node of the subring.
Summary of Contents for S7906E - Switch
Page 82: ...1 4 DeviceA interface tunnel 1 DeviceA Tunnel1 service loopback group 1...
Page 200: ...1 11 DeviceB display vlan dynamic No dynamic vlans exist...
Page 598: ...ii...
Page 1757: ...4 9...
Page 1770: ...6 4...
Page 2017: ...2 11 Figure 2 3 SFTP client interface...
Page 2238: ...1 16 DeviceA cfd linktrace service instance 1 mep 1001 target mep 4002...