1-7
z
All ports that connect service provider devices and customer devices and those that interconnect
service provider devices are trunk ports and allow packets of any VLAN to pass through.
z
PVST is enabled for VLANs 1 through 4094 on User A’s network. It is required that, after the
configuration, CE 1 and CE 2 implement consistent PVST calculation across the service provider
network, and that the destination multicast MAC address carried in BPDUs be
0x0100-0CCD-CDD0.
Figure 1-4
Network diagram for configuring BPDU tunneling for PVST
Configuration procedure
1) Configuration on PE 1
# Configure the destination multicast MAC address for BPDUs as 0x0100-0CCD-CDD0.
<PE1> system-view
[PE1] bpdu-tunnel tunnel-dmac 0100-0ccd-cdd0
# Configure GigabitEthernet 2/0/1 as a trunk port and assign it to all VLANs.
[PE1] interface gigabitethernet 2/0/1
[PE1-GigabitEthernet2/0/1] port link-type trunk
[PE1-GigabitEthernet2/0/1] port trunk permit vlan all
# Disable STP on GigabitEthernet 2/0/1, and then enable BPDU tunneling for STP and PVST on it.
[PE1-GigabitEthernet2/0/1] undo stp enable
[PE1-GigabitEthernet2/0/1] bpdu-tunnel dot1q stp
[PE1-GigabitEthernet2/0/1] bpdu-tunnel dot1q pvst
2) Configuration on PE 2
# Configure the destination multicast MAC address for BPDUs as 0x0100-0CCD-CDD0.
<PE2> system-view
[PE2] bpdu-tunnel tunnel-dmac 0100-0ccd-cdd0
# Configure GigabitEthernet 2/0/2 as a trunk port and assign it to all VLANs.
[PE2] interface gigabitethernet 2/0/2
[PE2-GigabitEthernet2/0/2] port link-type trunk
[PE2-GigabitEthernet2/0/2] port trunk permit vlan all
# Disable STP on GigabitEthernet 2/0/2, and then enable BPDU tunneling for STP and PVST on it.
[PE2-GigabitEthernet2/0/2] undo stp enable
[PE2-GigabitEthernet2/0/2] bpdu-tunnel dot1q stp
[PE2-GigabitEthernet2/0/2] bpdu-tunnel dot1q pvst
Summary of Contents for S7906E - Switch
Page 82: ...1 4 DeviceA interface tunnel 1 DeviceA Tunnel1 service loopback group 1...
Page 200: ...1 11 DeviceB display vlan dynamic No dynamic vlans exist...
Page 598: ...ii...
Page 1757: ...4 9...
Page 1770: ...6 4...
Page 2017: ...2 11 Figure 2 3 SFTP client interface...
Page 2238: ...1 16 DeviceA cfd linktrace service instance 1 mep 1001 target mep 4002...