Weights
44
RT-SVX24J-EN
Cabinet
Cabinet
-
8097
-
8315
-
9473
-
9473
-
9473
Cabinet - 4' Blank Section
-
935
-
935
-
901
-
901
-
901
Cabinet - 8' Blank Section
-
1709
-
1709
-
1682
-
1682
-
1682
Control Box - Main
Control Box - Main
-
519
-
519
-
519
-
519
-
519
Convenience Outlet
-
36
-
36
-
36
-
36
-
36
Low Ambient VFD
-
57
-
57
-
57
-
57
-
57
2/3 Piece Unit Adder
2 Piece Adder
-
406
-
406
-
406
-
406
-
406
3 Piece Adder
-
1157
-
1157
-
1236
-
1236
-
1236
Air-Cooled Condenser
Total Weight of Condenser Section
-
4637
-
5201
-
6015
-
6075
-
6092
(a) Evaporative Condenser weight includes the additional weight in the cabinet structure. coil weight and additional refrigerant charge. Add 1300 lbs for
operating sump base water weight.
(b) 2.5M includes weight associated with 12" of cabinet length.
(c) Energy Recovery includes weight associated w/ 96" of cabinet length.
Table 13.
Component weights (lbs) (continued)
90/100
105/118
120/128
130/140
150/162
Size
Weight Size
Weight Size
Weight Size
Weight Size
Weight
Table 14.
Roof curb weights — air-cooled (AC) and evaporative condensing (EC)
Tonnage
AC/EC
Energy
Recovery
Wheel
Blank Section
One-Piece
Unit
(a)
Two/Three
Piece Unit
90-105/100-118
No
None
907
1055
90-105/100-118
No
4 ft
988
1136
90-105/100-118
No
8 ft
1069
1217
90-105/100-118
Yes
None
1093
1240
90-105/100-118
Yes
4 ft
1174
1321
90-105/100-118
Yes
8 ft
N/A
1401
120-150/128-162 (All Units Except High Heat Gas models)
No
None
1040
1194
120-150/128-162 (All Units Except High Heat Gas models)
No
4 ft
1122
1275
120-150/128-162 (All Units Except High Heat Gas models)
No
8 ft
N/A
1357
120-150/128-162 (High Heat Gas Models Only)
No
None
1055
1209
120-150/128-162 (All Units Except High Heat Gas models)
Yes
None
N/A
1378
120-150/128-162 (All Units Except High Heat Gas models)
Yes
4 ft
N/A
1459
120-150/128-162 (All Units Except High Heat Gas models)
Yes
8 ft
N/A
1540
120-150/128-162 (High Heat Gas Models Only)
Yes
None
N/A
1393
(a) One-piece available with air-cooled condenser only.
Содержание SEHJ090-162
Страница 40: ...Dimensional Data 40 RT SVX24J EN Figure 13 Evaporative condenser water connection locations RIGHT SIDE VIEW ...
Страница 48: ...Installation 48 RT SVX24J EN Figure 18 Ductwork conversion ...
Страница 58: ...Installation 58 RT SVX24J EN Figure 36 5 Connected tubes 6 install panels Connected tubes 5 6 ...
Страница 75: ...Installation RT SVX24J EN 75 Figure 51 Hot water coil piping Figure 52 Steam coil piping ...
Страница 87: ...Installation RT SVX24J EN 87 Figure 57 Typical field wiring diagram for 90 to 162 ton CV control options ...
Страница 89: ...Installation RT SVX24J EN 89 Figure 59 Typical field wiring diagram for 90 to 162 ton VAV control options ...