RT-SVX24J-EN
7
Model Number Descriptions
DIGIT 18 — EXHAUST/RETURN
FAN MOTOR SELECTION
0
None
D
7.5 Hp
E
10 Hp
F
15 Hp
G
20 Hp
H
25 Hp
J
30 Hp
K
40 Hp
L
50 Hp
M
60 Hp
DIGIT 19 — EXHAUST/RETURN
RPM SELECTION
0
None
3
300
4
400
5
500
6
600
7
700
8
800
9
900
A
1000
B
1100
C
1200
D
1300
E
1400
DIGIT 20 — SYSTEM CONTROL
SELECTION
1
Constant Volume (CV) (Zone
Temperature Control)
2
CV w/ Discharge Temp Control
4
VAV w/ VFD Supply w/o Bypass
(Discharge Temp Control)
5
VAV w/ VFD Supply w/ Bypass
(Discharge Temp Control)
6
VAV – Single Zone VAV w/VFD w/o
Bypass (Zone Temperature Control)
7
VAV – Single Zone VAV w/VFD w/
Bypass (Zone Temperature Control)
DIGIT 21 — OUTSIDE AIR and
ECONOMIZER OPTION/
CONTROLS
A
0-25% Motorized Damper
B
Economizer w/Dry Bulb
C
Economizer w/Reference
Enthalpy
D
Economizer w/Comparative
Enthalpy
E
Econ w/TRAQ/DCV/Dry Bulb
1
F
Econ w/TRAQ/DCV/Ref
Enthalpy
1
G
Econ w/TRAQ/DCV/Comp Enthalpy
1
H
Econ w/DCV/Dry Bulb
1
J
Econ w/DCV/Ref Enthalpy
1
K
Econ w/DCV/Comp Enthalpy
1
1
Requires CO
2
Zone Sensor(s) for DCV to function
DIGIT 22 — DAMPER OPTION
0
Standard
1
Low Leak
2
Ultra Low Leak
DIGIT 23— PRE-EVAPORATOR
COIL FILTER SELECTION
0
Two Inch High Efficiency
Throwaway
1
Two Inch Throwaway Rack/Less
Filters
2
90-95% Bag Filters w/Prefilters
3
Bag Filter Rack/Less Filters
4
90-95% Cartridge Filters w/
Prefilters
5
Cartridge Rack/Less Filters
6
90-95% Low Pressure Drop
Cartridge Filters w/ Prefilters
7
Low Pressure Drop Cartridge
Rack/Less Filters
DIGIT 24 — BLANK SECTION
APPLICATION OPTIONS
0
None
A
90-95% Bag w/Prefilters
B
90-95% Low Pressure Drop
Cartridge w/ Prefilters
C
90-95%, Cartridge Filters w/
Prefilters
D
90-95% High Temp Cartridge
w/ Prefilters
E
HEPA w/Prefilters
F
High Temp HEPA w/Prefilters
DIGIT 25 — ENERGY RECOVERY
WHEEL
0
None
1
Low CFM ERW w/ Bypass Defrost
2
Standard CFM ERW w/ Bypass
Defrost
DIGIT 26 — UNIT MOUNTED
POWER CONNECTION
SELECTION
A
Terminal Block
B
Non-Fused Disconnect
C
Non-Fused Disconnect w/
Powered Convenience Outlet
D
Circuit Breaker w/ High Fault SCCR
E
Circuit Breaker w/ High Fault SCCR w/
Powered Convenience Outlet
DIGIT 27 — CONDENSER COIL
SELECTION
0
Air-Cooled Aluminum
A
Evap Condenser
B
Evap Condenser w/ Sump Heater
C
Evap Condenser w/ Dolphin
WaterCare™System
D
Evap Condenser w/ Dolphin
WaterCare™ System & Sump Heater
E
Evap Condenser w/ Conductivity
Controller
F
Evap Condenser w/ Conductivity
Controller and Sump Heater
J
Corrosion Protected Condenser Coil
2
DIGIT 28 — EVAPORATOR COIL
AND DRAIN PAN
0
Standard Evap Coil w/Galvanized
Drain Pan
A
Standard Evap Coil w/ Stainless
Steel Drain Pan
B
High Cap Evap Coil w/Galvanized
Drain Pan
C
High Cap Evap Coil w/Stainless
Steel Drain Pan
DIGIT 29 — REFRIGERATION
SYSTEM SELECTION A
0
Standard
A
Suction Service Valves
B
Replaceable Core Liquid Filter
Driers
C
Suction Service Valves &
Replaceable Core Liquid Filter
Driers
DIGIT 30 — REFRIGERATION
SYSTEM SELECTION B
0
Standard
1
Hot Gas Reheat
3
2
Hot Gas By-Pass
3
Hot Gas Reheat
3
/Hot Gas By-Pass
DIGIT 31 — AMBIENT CONTROL
OPTION
0
Standard Ambient
1
Low Ambient
DIGIT 32 — HIGH DUCT TEMP
THERMOSTAT
0
None
1
High Duct Temp Thermostat
DIGIT 33 — CONTROLS OPTION
0
None
1
Remote Human Interface (RHI) &
Inter-Processor Communication
Bridge (IPCB)
2
IPCB
3
Rapid Restart
2
Offered on Air-Cooled units
3
Humidity sensor required
Содержание SEHJ090-162
Страница 40: ...Dimensional Data 40 RT SVX24J EN Figure 13 Evaporative condenser water connection locations RIGHT SIDE VIEW ...
Страница 48: ...Installation 48 RT SVX24J EN Figure 18 Ductwork conversion ...
Страница 58: ...Installation 58 RT SVX24J EN Figure 36 5 Connected tubes 6 install panels Connected tubes 5 6 ...
Страница 75: ...Installation RT SVX24J EN 75 Figure 51 Hot water coil piping Figure 52 Steam coil piping ...
Страница 87: ...Installation RT SVX24J EN 87 Figure 57 Typical field wiring diagram for 90 to 162 ton CV control options ...
Страница 89: ...Installation RT SVX24J EN 89 Figure 59 Typical field wiring diagram for 90 to 162 ton VAV control options ...