Dimensional Data
34
RT-SVX24J-EN
Table 9.
Unit dimensions (in.)—three-piece unit evaporative condenser
THREE-PIECE Dimensions without Energy Recovery Wheel (ERW)
Tonnage
Blank
Section
Unit Dimensions
Lifting Lug Location
Air Handler Side
A
B
E
E1
E2
F
C1
C2
100/118
None
494 13/16
179 3/16
350 3/16
144 15/16
205 3/16
142 10/16
11 14/16
N/A
100/118
4 ft
543
179 3/16
398 6/16
144 15/16
253 7/16
142 10/16
11 14/16
N/A
100/118
8 ft
591 4/16
179 3/16
446 9/16
144 15/16
301 10/16
142 10/16
11 14/16
N/A
128-162 (All
Units Except
High Heat Gas
Models)
None
565 12/16
222 9/16
421 2/16
161 2/16
260
142 10/16
11 14/16
N/A
128-162 (All
Units Except
High Heat Gas
Models)
4 ft
613 15/16
222 9/16
469 5/16
161 2/16
308 4/16
142 10/16
11 14/16
N/A
128-162 (All
Units Except
High Heat Gas
Models)
8 ft
662 3/16
222 9/16
517 9/16
161 2/16
356 7/16
142 10/16
11 14/16
N/A
128-162 (High
Heat Gas
Models Only)
None
577 12/16
222 9/16
433 2/16
161 2/16
272
142 10/16
11 14/16
N/A
Tonnage
Blank
Section
Lifting Lug Locations
Unit Width
Air Handler Side
Condenser Side
C3
C4
C5
C6
D1
D2
M
N
100/118
None
138 9/16
151 6/16
272
339 11/16
16
133 11/16
139 13/16
143 8/16
100/118
4 ft
138 9/16
151 6/16
272
387 14/16
16
133 11/16
139 13/16
143 8/16
100/118
8 ft
138 9/16
151 6/16
272
436 1/16
16
133 11/16
139 13/16
143 8/16
128-162 (All
Units Except
High Heat Gas
Models)
None
155 2/16
167 5/16
294 14/16
410 10/16
16
133 11/16
139 13/16
143 8/16
128-162 (All
Units Except
High Heat Gas
Models)
4 ft
155 2/16
167 5/16
294 14/16
458 13/16
16
133 11/16
139 13/16
143 8/16
128-162 (All
Units Except
High Heat Gas
Models)
8 ft
155 2/16
167 5/16
294 14/16
507 1/16
16
133 11/16
139 13/16
143 8/16
128-162 (High
Heat Gas
Models Only)
None
155 2/16
167 5/16
294 14/16
422 10/16
16
133 11/16
139 13/16
143 8/16
continued on next page
Содержание SEHJ090-162
Страница 40: ...Dimensional Data 40 RT SVX24J EN Figure 13 Evaporative condenser water connection locations RIGHT SIDE VIEW ...
Страница 48: ...Installation 48 RT SVX24J EN Figure 18 Ductwork conversion ...
Страница 58: ...Installation 58 RT SVX24J EN Figure 36 5 Connected tubes 6 install panels Connected tubes 5 6 ...
Страница 75: ...Installation RT SVX24J EN 75 Figure 51 Hot water coil piping Figure 52 Steam coil piping ...
Страница 87: ...Installation RT SVX24J EN 87 Figure 57 Typical field wiring diagram for 90 to 162 ton CV control options ...
Страница 89: ...Installation RT SVX24J EN 89 Figure 59 Typical field wiring diagram for 90 to 162 ton VAV control options ...