Dimensional Data
36
RT-SVX24J-EN
Tonnage
Blank
Section
Lifting Lug Locations
Air Handler Side
Condenser Side
Unit Width
C3
C4
C5
C6
D1
D2
M
N
100/118
None
234 13/16
247 13/16
368 7/16
436 2/16
16
133 11/16
139 13/16
143 8/16
100/118
4 ft
234 13/16
247 13/16
368 7/16
484 5/16
16
133 11/16
139 13/16
143 8/16
100/118
8 ft
234 13/16
247 13/16
368 7/16
532 8/16
16
133 11/16
139 13/16
143 8/16
128-162 (All
Units Except
High Heat Gas
Models)
None
252 12/16
263 12/16
391 5/16
519 1/16
16
133 11/16
139 13/16
143 8/16
128-162 (All
Units Except
High Heat Gas
Models)
4 ft
252 12/16
263 12/16
391 5/16
507 1/16
16
133 11/16
139 13/16
143 8/16
128-162 (All
Units Except
High Heat Gas
Models)
4 ft
252 12/16
263 12/16
391 5/16
507 1/16
16
133 11/16
139 13/16
143 8/16
128-162 (All
Units Except
High Heat Gas
Models)
8 ft
252 12/16
263 12/16
391 5/16
555 4/16
16
133 11/16
139 13/16
143 8/16
128-162 (High
Heat Gas
Models Only)
None
252 12/16
263 12/16
391 5/16
603 7/16
16
133 11/16
139 13/16
143 8/16
Tonnage
Blank
Section
Unit Height
Return Fan
Exhaust
Fan
O
P
R
J
K
100-162
None
103 12/16
97 9/16
102 12/16
N/A
17
100-162
4 ft
103 12/16
97 9/16
102 12/16
N/A
17
100-162
8 ft
103 12/16
97 9/16
102 12/16
N/A
17
Table 9.
Unit dimensions (in.)—three-piece unit evaporative condenser (continued)
Table 10.
Downflow/horizontal airflow configuration dimensions (in.) air cooled (AC) and evap condenser (EC) without
energy recovery wheel (ERW)
Tonnage
Blank
Section
Gas
Heat
DOWNFLOW Opening Dimensions
Return Opening—with or
without Exhaust Fan
Return Opening—with Return Fan
X1
Y1
W1
L1
X1
Y1
W1
L1
90-105/100-118
None
None
14 13/16
8 14/16
48 3/16
121 15/16
14 13/16
42 14/16
48 3/16
53 14/16
90-105/100-118
4 ft
None
14 13/16
8 14/16
48 3/16
121 15/16
14 13/16
42 14/16
48 3/16
53 14/16
90-105/100-118
8 ft
None
14 13/16
8 14/16
48 3/16
121 15/16
14 13/16
42 14/16
48 3/16
53 14/16
120-150/128-162
None
None
14 13/16
8 14/16
48 3/16
121 15/16
14 13/16
42 14/16
48 3/16
53 14/16
120-150/128-162
4 ft
None
14 13/16
8 14/16
48 3/16
121 15/16
14 13/16
42 14/16
48 3/16
53 14/16
120-150/128-162
8 ft
None
14 13/16
8 14/16
48 3/16
121 15/16
14 13/16
42 14/16
48 3/16
53 14/16
90-105/100-118
None
Low/Med
14 13/16
8 14/16
48 3/16
121 15/16
14 13/16
42 14/16
48 3/16
53 14/16
90-105/100-118
8 ft
Low/Med
14 13/16
8 14/16
48 3/16
121 15/16
14 13/16
42 14/16
48 3/16
53 14/16
120-150/128-162
None
Low/Med
14 13/16
8 14/16
48 3/16
121 15/16
14 13/16
42 14/16
48 3/16
53 14/16
120-150/128-162
8 ft
Low/Med
14 13/16
8 14/16
48 3/16
121 15/16
14 13/16
42 14/16
48 3/16
53 14/16
120-150/128-162
None
High
14 13/16
8 14/16
48 3/16
121 15/16
14 13/16
42 14/16
48 3/16
53 14/16
continued on next page
Содержание SEHJ090-162
Страница 40: ...Dimensional Data 40 RT SVX24J EN Figure 13 Evaporative condenser water connection locations RIGHT SIDE VIEW ...
Страница 48: ...Installation 48 RT SVX24J EN Figure 18 Ductwork conversion ...
Страница 58: ...Installation 58 RT SVX24J EN Figure 36 5 Connected tubes 6 install panels Connected tubes 5 6 ...
Страница 75: ...Installation RT SVX24J EN 75 Figure 51 Hot water coil piping Figure 52 Steam coil piping ...
Страница 87: ...Installation RT SVX24J EN 87 Figure 57 Typical field wiring diagram for 90 to 162 ton CV control options ...
Страница 89: ...Installation RT SVX24J EN 89 Figure 59 Typical field wiring diagram for 90 to 162 ton VAV control options ...