42
RT-SVX24J-EN
Weights
Notes:
1. Weights shown for air-cooled units include the following features: standard coils, 0-25% outside air, throwaway filters, low CFM supply fan, minimum
motor sizes, constant volume, 460 XL, No heat. Weights shown for Evaporative condensing units include high-capacity evaporator coil and the weight
of the extra structure associated with a two piece unit.
2. Weights shown represent approximate operating weights and have a + 5% accuracy. To calculate weight for a specific unit configuration, utilize TOPSS
or contact the local Trane sales representative. ACTUAL WEIGHTS ARE STAMPED ON THE UNIT NAMEPLATE.
Table 12.
Approximate operating weights (lbs.)
Air-Cooled Condensers
Evaporative Condensers
Nominal Tons
Unit (Minimum)
Roof Curb
(Minimum)
Nominal Tons
Unit (Minimum)
Roof Curb
(Minimum)
90
14197
907
100
18430
1055
105
14792
907
118
18941
1055
120
16939
1040
128
21362
1194
130
17690
1040
140
21348
1194
150
17923
1040
162
21470
1194
Table 13.
Component weights (lbs)
90/100
105/118
120/128
130/140
150/162
Size
Weight Size
Weight Size
Weight Size
Weight Size
Weight
Refrigeration
Compressor Assembly
-
1126
-
1344
-
1562
-
1616
-
1670
Air-Cooled Condensing Coil (Al)
-
623
-
722
-
1049
-
1224
-
924
Evaporative Condensing Coil
(a)
4566
4329
4129
4109
4029
Evap Coil - Std. Cap
-
1034
-
1300
-
1664
-
1892
-
2564
Evap Coil - Hi. Cap.
-
1382
-
1462
-
2564
-
2496
-
N/A
Reheat Coil & Tubing
-
292
-
294
-
367
-
367
-
367
Replaceable Core Filter Driers
-
26
-
25
-
35
-
35
-
35
HGBP
-
46
-
49
-
53
-
53
-
53
Supply Fan Assembly
Supply Fan & Fan Board Assembly - Low CFM
25"
1159
32"
1361
32"
1361
32"
1361
32"
1361
Supply Fan & Fan Board Assembly - Std. CFM
36"
1490
36"
1490
40"
1653
40"
1653
40"
1653
Belt Guard
-
116
-
116
-
116
-
116
-
116
Supply VFD (50 hp and below)
-
233
-
233
-
233
-
233
-
233
Supply VFD (60-100 hp)
-
284
-
284
-
284
-
284
-
284
Supply-Exhaust Fan Motor - 15 hp
-
181
-
181
-
181
-
181
-
181
Supply-Exhaust Fan Motor - 20 hp
-
206
-
206
-
206
-
206
-
206
Supply-Exhaust Fan Motor - 25 hp
-
358
-
358
-
358
-
358
-
358
Supply-Exhaust Fan Motor - 30 hp
-
413
-
413
-
413
-
413
-
413
Supply-Exhaust Fan Motor - 40 hp
-
495
-
495
-
495
-
495
-
495
Supply-Exhaust Fan Motor - 50 hp
-
604
-
604
-
604
-
604
-
604
Supply-Exhaust Fan Motor - 60 hp
-
776
-
776
-
776
-
776
-
776
Supply-Exhaust Fan Motor - 75 hp
-
879
-
879
-
879
-
879
-
879
Supply-Exhaust Fan Motor - 100 hp
-
1102
-
1102
-
1102
-
1102
-
1102
Return/Exhaust Fan Assembly
Return Fan & Dampers - Low CFM
36"
2294
36"
2294
36"
2294
36"
2294
36"
2294
Return Fan & Dampers - Std. CFM
40"
2343
40"
2343
44"
2445
44"
2445
44"
2445
Exhaust Fan & Dampers - Low CFM
25"
889
28"
979
28"
979
28"
979
28"
979
Exhaust Fan & Dampers - Std. CFM
28"
979
32"
1429
32"
1429
32"
1429
32"
1429
Belt Guard
-
119
-
119
-
119
-
119
-
119
Exhaust VFD (50 hp and below)
-
244
-
244
-
244
-
244
-
244
Содержание SEHJ090-162
Страница 40: ...Dimensional Data 40 RT SVX24J EN Figure 13 Evaporative condenser water connection locations RIGHT SIDE VIEW ...
Страница 48: ...Installation 48 RT SVX24J EN Figure 18 Ductwork conversion ...
Страница 58: ...Installation 58 RT SVX24J EN Figure 36 5 Connected tubes 6 install panels Connected tubes 5 6 ...
Страница 75: ...Installation RT SVX24J EN 75 Figure 51 Hot water coil piping Figure 52 Steam coil piping ...
Страница 87: ...Installation RT SVX24J EN 87 Figure 57 Typical field wiring diagram for 90 to 162 ton CV control options ...
Страница 89: ...Installation RT SVX24J EN 89 Figure 59 Typical field wiring diagram for 90 to 162 ton VAV control options ...