Dimensional Data
RT-SVX24J-EN
37
Tonnage
Blank
Section
Gas
Heat
DOWNFLOW Opening Dimensions
Supply Opening
X2
(One or
Two-Piece
Models)
X2
(Three-
Piece
Models)
Y2
W2
L2
90-105/100-118
None
None
256 1/16
275 6/16
13
47 14/16
102 8/16
90-105/100-118
4 ft
None
304 4/16
323 9/16
13
47 14/16
102 8/16
90-105/100-118
8 ft
None
352 8/16
371 12/16
13
47 14/16
102 8/16
120-150/128-162
None
None
320 13/16
346 4/16
13
47 14/16
102 8/16
120-150/128-162
4 ft
None
369 394 8/16
13
47 14/16
102 8/16
120-150/128-162
8 ft
None
417 3/16
442 11/16
13
47 14/16
102 8/16
90-105/100-118 None
Low/Med/
High
256 1/16
275 6/16
13
47 14/16
102 8/16
90-105/100-118
8 ft
Low/Med/
High
352 8/16
371 12/16
13
47 14/16
102 8/16
120-150/128-162
None
Low/Med 320 13/16
346 4/16
13
47 14/16
102 8/16
120-150/128-162
8 ft
Low/Med
417 3/16
442 11/16
13
47 14/16
102 8/16
120-150/128-162
None
High
320 13/16
346 4/16
13
59 14/16
102 8/16
Tonnage
Blank
Section
Gas
Heat
HORIZONTAL Opening Dimensions
Return Side Opening
Return End Opening
X3
Y3
W3
H1
Y1
Y3
H3
L1
90-105/100-118
None
None
9 5/16
10 10/16
54 12/16
84 15/16
6 5/16
8 3/16
35 3/16
127 2/16
90-105/100-118
4 ft
None
9 5/16
10 10/16
54 12/16
84 15/16
6 5/16
8 3/16
35 3/16
127 2/16
90-105/100-118
8 ft
None
9 5/16
10 10/16
54 12/16
84 15/16
6 5/16
8 3/16
35 3/16
127 2/16
120-150/128-162
8 ft
None
9 5/16
10 10/16
54 12/16
84 15/16
6 5/16
8 3/16
35 3/16
127 2/16
90-105/100-118
None
Low/Med
9 5/16
10 10/16
54 12/16
84 15/16
6 5/16
8 3/16
35 3/16
127 2/16
90-105/100-118
8 ft
Low/Med
9 5/16
10 10/16
54 12/16
84 15/16
6 5/16
8 3/16
35 3/16
127 2/16
120-150/128-162
None
Low/Med
9 5/16
10 10/16
54 12/16
84 15/16
6 5/16
8 3/16
35 3/16
127 2/16
120-150/128-162
8 ft
Low/Med
9 5/16
10 10/16
54 12/16
84 15/16
6 5/16
8 3/16
35 3/16
127 2/16
120-150/128-162
None
High
9 5/16
10 10/16
54 12/16
84 15/16
6 5/16
8 3/16
35 3/16
127 2/16
Tonnage
Blank
Section
Gas
Heat
Supply Opening
X4 (One or
Two-Piece
Models)
X4
(Three-
Piece
Models)
Y4
W4
H2
90-105/100-118
None
None
254 12/16
274 10 10/16
54 12/16
84 15/16
90-105/100-118
4 ft
None
302 15/16
322 4/16
10 10/16
54 12/16
84 15/16
90-105/100-118
8 ft
None
351 2/16
370 7/16
10 10/16
54 12/16
84 15/16
120-150/128-162
None
None
319 8/16
345 10 10/16
54 12/16
84 15/16
120-150/128-162
4 ft
None
367 11/16
393 3/16
10 10/16
54 12/16
84 15/16
120-150/128-162
8 ft
None
415 15/16
441 6/16
10 10/16
54 12/16
84 15/16
90-105/100-118
None
Low/Med 254 12/16
274 10 10/16
54 12/16
66 11/16
90-105/100-118
8 ft
Low/Med
351 2/16
370 7/16
10 10/16
54 12/16
84 15/16
120-150/128-162
None
Low/Med
319 8/16
345 10 10/16
54 12/16
66 11/16
120-150/128-162
8 ft
Low/Med 415 15/16
441 6/16
10 10/16
54 12/16
84 15/16
120-150/128-162
None
High
319 8/16
345 10 10/16
66 12/16
66 11/16
Table 10.
Downflow/horizontal airflow configuration dimensions (in.) air cooled (AC) and evap condenser (EC) without
energy recovery wheel (ERW) (continued)
Содержание SEHJ090-162
Страница 40: ...Dimensional Data 40 RT SVX24J EN Figure 13 Evaporative condenser water connection locations RIGHT SIDE VIEW ...
Страница 48: ...Installation 48 RT SVX24J EN Figure 18 Ductwork conversion ...
Страница 58: ...Installation 58 RT SVX24J EN Figure 36 5 Connected tubes 6 install panels Connected tubes 5 6 ...
Страница 75: ...Installation RT SVX24J EN 75 Figure 51 Hot water coil piping Figure 52 Steam coil piping ...
Страница 87: ...Installation RT SVX24J EN 87 Figure 57 Typical field wiring diagram for 90 to 162 ton CV control options ...
Страница 89: ...Installation RT SVX24J EN 89 Figure 59 Typical field wiring diagram for 90 to 162 ton VAV control options ...