Service Literature
CHA/CHP16
CHP20
2 to 5 ton (7.0 to 17.6 kW)
CHA/CHP16, CHP20 SERIES UNITS
CHA/CHP16 and CHP20 series units in the 2 through 5 ton
(7.0 through 17.6 kW) sizes are designed for outdoor roofĆ
top or ground level installations in light commercial applicaĆ
tions. Electric heat is available in several kW sizes. Models
are available in single or three phase power supply and can
be utilized in downflow or horizontal supply and return air.
CHA/CHP16-024/030 model units are equipped with a
reciprocating compressor. CHA/CHP16-036/060 and
CHP20-024/060 model units are equipped with scroll
compressors. The scroll compressor offers high voluĆ
metric efficiency, quiet operation and the ability to start
under system load. Continuous flank contact, mainĆ
tained by centrifugal force, minimizes gas leakage and
maximizes efficiency. The motor is internally protected
from excessive current and temperature.
CHA/CHP16 and CHP20 model units are designed to acĆ
cept any of several different thermostat control systems
with minimum field wiring. Control options such as econĆ
omizer, warm up kit, Honeywell T7300 thermostat or
Honeywell T8600/T8611/T8621 thermostat controls
connect to the unit with jackĆplugs. When plugged in the
controls become an integral part of the unit wiring. Low
voltage thermostat connections facilitate thermostat
field wiring.
Optional electric heat is field installed. Electric heat operĆ
ates in single or multiple stages depending on the kW size.
5kW through 25 kW sizes are available for the CHA/CHP16
and CHP20 units.
Information in this manual is for use by a qualified service
technicial only. All specifications in this manual are subject
to change. Procedures outlined in this manual are repesĆ
ented as a recommendation only and do not supersede or
replace state or local codes.
IMPORTANT
Improper installation, adjustment, alteration, service
or maintenance can cause property damage, personĆ
al injury or loss of life. Installation and service must
be performed by a qualified installer, service agency
or the gas supplier.
WARNING
Electric shock hazard. Can cause injury
or death. Before attempting to perform
any service or maintenance, turn the
electrical power to unit OFF at disconĆ
nect switch(es). Unit may have multiple
power supplies.
WARNING
Refrigerant can be harmful if it is inhaled. Refrigerant
must be used and recovered responsibly.
Failure to follow this warning may result in personal
injury or death.