![Texas Instruments SimpleLink Ethernet MSP432E401Y Скачать руководство пользователя страница 771](http://html1.mh-extra.com/html/texas-instruments/simplelink-ethernet-msp432e401y/simplelink-ethernet-msp432e401y_technical-reference-manual_1095578771.webp)
ADC Registers
771
SLAU723A – October 2017 – Revised October 2018
Copyright © 2017–2018, Texas Instruments Incorporated
Analog-to-Digital Converter (ADC)
10.5.31 ADCSSOP3 Register (Offset = 0xB0) [reset = 0x0]
ADC Sample Sequence 3 Operation (ADCSSOP3)
This register determines whether the sample from the given conversion on Sample Sequence 3 is saved
in the Sample Sequence 3 FIFO or sent to the digital comparator unit.
ADCSSOP3 is shown in
and described in
Return to
Figure 10-45. ADCSSOP3 Register
31
30
29
28
27
26
25
24
RESERVED
R-0x0
23
22
21
20
19
18
17
16
RESERVED
R-0x0
15
14
13
12
11
10
9
8
RESERVED
R-0x0
7
6
5
4
3
2
1
0
RESERVED
S0DCOP
R-0x0
R/W-0x0
Table 10-40. ADCSSOP3 Register Field Descriptions
Bit
Field
Type
Reset
Description
31-1
RESERVED
R
0x0
0
S0DCOP
R/W
0x0
Sample 0 Digital Comparator Operation.
0x0 = The sample is saved in Sample Sequence FIFO3.
0x1 = The sample is sent to the digital comparator unit specified by
the S0DCSEL bit in the ADCSSDC03 register, and the value is not
written to the FIFO.