ADC Registers
769
SLAU723A – October 2017 – Revised October 2018
Copyright © 2017–2018, Texas Instruments Incorporated
Analog-to-Digital Converter (ADC)
10.5.29 ADCSSMUX3 Register (Offset = 0xA0) [reset = 0x0]
ADC Sample Sequence Input Multiplexer Select 3 (ADCSSMUX3)
This register, along with the ADCSSEMUX3 register, defines the analog input configuration for the sample
in a sequence executed with Sample Sequencer 3. If the EMUX0 bit in the ADCSSEMUX3 register is set,
the MUX0 field in this register selects from AIN[23:16]. When the EMUX0 bit is clear, the MUX0 field
selects from AIN[15:0]. This register is four bits wide and contains information for one possible sample.
See the ADCSSMUX0 register in
for detailed bit descriptions.
ADCSSMUX3 is shown in
and described in
Return to
Figure 10-43. ADCSSMUX3 Register
31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10
9
8
7
6
5
4
3
2
1
0
RESERVED
MUX0
R-0x0
R/W-0x0
Table 10-38. ADCSSMUX3 Register Field Descriptions
Bit
Field
Type
Reset
Description
31-4
RESERVED
R
0x0
3-0
MUX0
R/W
0x0
1st Sample Input Select.