System Control Registers
345
SLAU723A – October 2017 – Revised October 2018
Copyright © 2017–2018, Texas Instruments Incorporated
System Control
4.2.104 RCGCOWIRE Register (Offset = 0x698) [reset = 0x0]
1-Wire Run Mode Clock Gating Control (RCGCOWIRE)
The RCGCOWIRE register lets software enable and disable the 1-Wire module in run mode. When
enabled, a module is provided a clock, and accesses to module registers are allowed. When disabled, the
clock is disabled to save power, and accesses to module registers generate a bus fault.
NOTE:
This register controls the clocking for the 1-Wire module.
RCGCOWIRE is shown in
and described in
.
Return to
Figure 4-110. RCGCOWIRE Register
31
30
29
28
27
26
25
24
23
22
21
20
19
18
17
16
RESERVED
R-0x0
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
RESERVED
R0
R-0x0
R/W-
0x0
Table 4-117. RCGCOWIRE Register Field Descriptions
Bit
Field
Type
Reset
Description
31-1
RESERVED
R
0x0
0
R0
R/W
0x0
1-Wire Module 0 Run Mode Clock Gating Control
0x0 = 1-Wire module 0 is disabled.
0x1 = Enable and provide a clock to 1-Wire module 0 in run mode.