![Texas Instruments SimpleLink Ethernet MSP432E401Y Скачать руководство пользователя страница 1075](http://html1.mh-extra.com/html/texas-instruments/simplelink-ethernet-msp432e401y/simplelink-ethernet-msp432e401y_technical-reference-manual_10955781075.webp)
MII Management (EPHY) Registers
1075
SLAU723A – October 2017 – Revised October 2018
Copyright © 2017–2018, Texas Instruments Incorporated
Ethernet Controller
15.7.21 EPHYBISTCR Register (Address = 0x16) [reset = 0x100]
Ethernet PHY BIST Control - MR22 (EPHYBISTCR)
This register is used for Build-In Self Test (BIST) configuration. The BIST functionality provides Pseudo
Random Bit Stream (PRBS) mechanism including packet generation generator and checker. Selection of
the exact loopback point in the signal chain is also done in this register.
EPHYBISTCR is shown in
and described in
Return to
Figure 15-109. EPHYBISTCR Register
15
14
13
12
11
10
9
8
RESERVED
PRBSM
PRBSPKT
PKTEN
PRBSCHKLK
PRBSCHKSYN
C
PKTGENSTAT
PWRMODE
R-0x0
R/W-0x0
R/W-0x0
R/W-0x0
R-0x0
R-0x0
R-0x0
R-0x1
7
6
5
4
3
2
1
0
RESERVED
TXMIILB
RESERVED
LBMODE
R-0x0
R-0x0
R-0x0
R/W-0x0
Table 15-121. EPHYBISTCR Register Field Descriptions
Bit
Field
Type
Reset
Description
15
RESERVED
R
0x0
14
PRBSM
R/W
0x0
PRBS Single/Continuous Mode.
0x0 = Single mode selected. When BIST Error Counter reaches its
max value, the PRBS checker stops counting.
0x1 = Continuous mode selected. When the PRBS counters reach
maximum count value, the counter starts counting from zero again.
13
PRBSPKT
R/W
0x0
Generated PRBS Packets.
0x0 = When packet generator is enabled, generate a single packet
with constant data. PRBS generation and check is disabled.
0x1 = When packet generator is enabled, generate continuous
packets with PRBS data. When packet generator is disabled, PRBS
checker is still enabled.
12
PKTEN
R/W
0x0
Packet Generation Enable.
0x0 = Disable packet generator
0x1 = Enable packet generation with PRBS data
11
PRBSCHKLK
R
0x0
PRBS Checker Lock Indication.
0x0 = PRBS checker is not locked
0x1 = PRBS checker is locked and synchronized on received bit
stream
10
PRBSCHKSYNC
R
0x0
PRBS Checker Lock Sync Loss Indication.
0x0 = PRBS checker has not lost synchronization.
0x1 = PRBS checker has lost synchronization on received bit
stream. This is an error indication.
9
PKTGENSTAT
R
0x0
Packet Generator Status Indication.
0x0 = Packet Generator is disabled.
0x1 = Packet Generator is active and generate packets.
8
PWRMODE
R
0x1
Power Mode Indication.
0x0 = Indicates that the PHY is in one of the sleep modes, either
active or passive.
0x1 = Indicates that the PHY is in normal power mode.
7
RESERVED
R
0x0