System Control Registers
325
SLAU723A – October 2017 – Revised October 2018
Copyright © 2017–2018, Texas Instruments Incorporated
System Control
4.2.86 RCGCTIMER Register (Offset = 0x604) [reset = 0x00]
16/32-Bit General-Purpose Timer Run Mode Clock Gating Control (RCGCTIMER)
The RCGCGPT32 register lets software enable and disable 16/32-bit timer modules in run mode. When
enabled, a module is provided a clock, and accesses to module registers are allowed. When disabled, the
clock is disabled to save power, and accesses to module registers generate a bus fault.
NOTE:
This register controls the clocking for the timer modules.
RCGCTIMER is shown in
and described in
.
Return to
Figure 4-92. RCGCTIMER Register
31
30
29
28
27
26
25
24
23
22
21
20
19
18
17
16
RESERVED
R-0x0
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
RESERVED
R7
R6
R5
R4
R3
R2
R1
R0
R-0x0
R/W-
0x0
R/W-
0x0
R/W-
0x0
R/W-
0x0
R/W-
0x0
R/W-
0x0
R/W-
0x0
R/W-
0x0
Table 4-99. RCGCTIMER Register Field Descriptions
Bit
Field
Type
Reset
Description
31-8
RESERVED
R
0x0
7
R7
R/W
0x0
16/32-Bit General-Purpose Timer 7 Run Mode Clock Gating Control
0x0 = 16/32-bit general-purpose timer module 7 is disabled.
0x1 = Enable and provide a clock to 16/32-bit general-purpose timer
module 7 in run mode.
6
R6
R/W
0x0
16/32-Bit General-Purpose Timer 6 Run Mode Clock Gating Control
0x0 = 16/32-bit general-purpose timer module 6 is disabled.
0x1 = Enable and provide a clock to 16/32-bit general-purpose timer
module 6 in run mode.
5
R5
R/W
0x0
16/32-Bit General-Purpose Timer 5 Run Mode Clock Gating Control
0x0 = 16/32-bit general-purpose timer module 5 is disabled.
0x1 = Enable and provide a clock to 16/32-bit general-purpose timer
module 5 in run mode.
4
R4
R/W
0x0
16/32-Bit General-Purpose Timer 4 Run Mode Clock Gating Control
0x0 = 16/32-bit general-purpose timer module 4 is disabled.
0x1 = Enable and provide a clock to 16/32-bit general-purpose timer
module 4 in run mode.
3
R3
R/W
0x0
16/32-Bit General-Purpose Timer 3 Run Mode Clock Gating Control
0x0 = 16/32-bit general-purpose timer module 3 is disabled.
0x1 = Enable and provide a clock to 16/32-bit general-purpose timer
module 3 in run mode.
2
R2
R/W
0x0
16/32-Bit General-Purpose Timer 2 Run Mode Clock Gating Control
0x0 = 16/32-bit general-purpose timer module 2 is disabled.
0x1 = Enable and provide a clock to 16/32-bit general-purpose timer
module 2 in run mode.
1
R1
R/W
0x0
16/32-Bit General-Purpose Timer 1 Run Mode Clock Gating Control
0x0 = 16/32-bit general-purpose timer module 1 is disabled.
0x1 = Enable and provide a clock to 16/32-bit general-purpose timer
module 1 in run mode.
0
R0
R/W
0x0
16/32-Bit General-Purpose Timer 0 Run Mode Clock Gating Control
0x0 = 16/32-bit general-purpose timer module 0 is disabled.
0x1 = Enable and provide a clock to 16/32-bit general-purpose timer
module 0 in run mode.