![Texas Instruments SimpleLink Ethernet MSP432E401Y Скачать руководство пользователя страница 746](http://html1.mh-extra.com/html/texas-instruments/simplelink-ethernet-msp432e401y/simplelink-ethernet-msp432e401y_technical-reference-manual_1095578746.webp)
ADC Registers
746
SLAU723A – October 2017 – Revised October 2018
Copyright © 2017–2018, Texas Instruments Incorporated
Analog-to-Digital Converter (ADC)
10.5.15 ADCSSMUX0 Register (Offset = 0x40) [reset = 0x0]
ADC Sample Sequence Input Multiplexer Select 0 (ADCSSMUX0)
This register, along with the ADCSSEMUX0 register, defines the analog input configuration for each
sample in a sequence executed with Sample Sequencer 0. If the corresponding EMUXn bit in the
ADCSSEMUX0 register is set, the MUXn field in this register selects from AIN[23:16]. When the
corresponding EMUXn bit is clear, the MUXn field selects from AIN[15:0]. This register is 32 bits wide and
contains information for eight possible samples.
NOTE:
Channels AIN[31:24] do not exist on this microcontroller. Configuring MUXn to be 0x8 -0xF
when the corresponding EMUXn bit is set results in undefined behavior.
ADCSSMUX0 is shown in
and described in
Return to
Figure 10-29. ADCSSMUX0 Register
31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10
9
8
7
6
5
4
3
2
1
0
MUX7
MUX6
MUX5
MUX4
MUX3
MUX2
MUX1
MUX0
R/W-0x0
R/W-0x0
R/W-0x0
R/W-0x0
R/W-0x0
R/W-0x0
R/W-0x0
R/W-0x0
Table 10-22. ADCSSMUX0 Register Field Descriptions
Bit
Field
Type
Reset
Description
31-28
MUX7
R/W
0x0
8th Sample Input Select.
The MUX7 field is used during the eighth sample of a sequence
executed with the sample sequencer.
It specifies which of the analog inputs is sampled for the analog-to-
digital conversion.
The value set here indicates the corresponding pin, for example, a
value of 0x1 when EMUX7 is clear indicates the input is AIN1.
A value of 0x1 when EMUX7 is set indicates the input is AIN17.
If differential sampling is enabled (the D7 bit in the ADCSSCTL0
register is set), this field must be set to the pair number "i", where
the paired inputs are "2i and 2i+1".
27-24
MUX6
R/W
0x0
7th Sample Input Select.
The MUX6 field is used during the seventh sample of a sequence
executed with the sample sequencer.
It specifies which of the analog inputs is sampled for the analog-to-
digital conversion.
23-20
MUX5
R/W
0x0
6th Sample Input Select.
The MUX5 field is used during the sixth sample of a sequence
executed with the sample sequencer.
It specifies which of the analog inputs is sampled for the analog-to-
digital conversion.
19-16
MUX4
R/W
0x0
5th Sample Input Select.
The MUX4 field is used during the fifth sample of a sequence
executed with the sample sequencer.
It specifies which of the analog inputs is sampled for the analog-to-
digital conversion.
15-12
MUX3
R/W
0x0
4th Sample Input Select.
The MUX3 field is used during the fourth sample of a sequence
executed with the sample sequencer.
It specifies which of the analog inputs is sampled for the analog-to-
digital conversion.
11-8
MUX2
R/W
0x0
3rd Sample Input Select.
The MUX2 field is used during the third sample of a sequence
executed with the sample sequencer.
It specifies which of the analog inputs is sampled for the analog-to-
digital conversion.