![Texas Instruments SimpleLink Ethernet MSP432E401Y Скачать руководство пользователя страница 228](http://html1.mh-extra.com/html/texas-instruments/simplelink-ethernet-msp432e401y/simplelink-ethernet-msp432e401y_technical-reference-manual_1095578228.webp)
System Control Registers
228
SLAU723A – October 2017 – Revised October 2018
Copyright © 2017–2018, Texas Instruments Incorporated
System Control
Table 4-14. RIS Register Field Descriptions (continued)
Bit
Field
Type
Reset
Description
1
BORRIS
R
0x0
Brownout Reset Raw Interrupt Status.
The appropriate BOR bit in the PTBOCTL register must be set to an
interrupt (0x1) encoding to generate an interrupt. . This bit is cleared
by writing 1 to the BORMIS bit in the MISC register.
0x0 = A brownout condition is not currently active.
0x1 = A brownout condition is currently active.
0
RESERVED
R
0x0