ADC Registers
765
SLAU723A – October 2017 – Revised October 2018
Copyright © 2017–2018, Texas Instruments Incorporated
Analog-to-Digital Converter (ADC)
10.5.26 ADCSSDC1 and ADCSSDC2 Registers [reset = 0x0]
ADC Sample Sequence 1 Digital Comparator Select (ADCSSDC1), offset 0x074
ADC Sample Sequence 2 Digital Comparator Select (ADCSSDC2), offset 0x094
These registers determine which digital comparator receives the sample from the given conversion on
Sample Sequence n if the corresponding SnDCOP bit in the ADCSSOPn register is set. The ADCSSDC1
register controls the selection for Sample Sequencer 1 and the ADCSSDC2 register controls the selection
for Sample Sequencer 2.
ADCSSDCn is shown in
and described in
Return to
Figure 10-40. ADCSSDCn Register
31
30
29
28
27
26
25
24
23
22
21
20
19
18
17
16
RESERVED
R-0x0
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
S3DCSEL
S2DCSEL
S1DCSEL
S0DCSEL
R/W-0x0
R/W-0x0
R/W-0x0
R/W-0x0
Table 10-34. ADCSSDCn Register Field Descriptions
Bit
Field
Type
Reset
Description
31-16
RESERVED
R
0x0
15-12
S3DCSEL
R/W
0x0
Sample 3 Digital Comparator Select.
When the S3DCOP bit in the ADCSSOPn register is set, this field
indicates which digital comparator unit (and its associated set of
control registers) receives the eighth sample from Sample
Sequencer n.
Values not listed are reserved.
0x0 = Digital Comparator Unit 0 (ADCDCCMP0 and ADCCCTL0)
0x1 = Digital Comparator Unit 1 (ADCDCCMP1 and ADCCCTL1)
0x2 = Digital Comparator Unit 2 (ADCDCCMP2 and ADCCCTL2)
0x3 = Digital Comparator Unit 3 (ADCDCCMP3 and ADCCCTL3)
0x4 = Digital Comparator Unit 4 (ADCDCCMP4 and ADCCCTL4)
0x5 = Digital Comparator Unit 5 (ADCDCCMP5 and ADCCCTL5)
0x6 = Digital Comparator Unit 6 (ADCDCCMP6 and ADCCCTL6)
0x7 = Digital Comparator Unit 7 (ADCDCCMP7 and ADCCCTL7)
11-8
S2DCSEL
R/W
0x0
Sample 2 Digital Comparator Select.
This field has the same encodings as S3DCSEL but is used during
the third sample.
7-4
S1DCSEL
R/W
0x0
Sample 1 Digital Comparator Select.
This field has the same encodings as S3DCSEL but is used during
the second sample.
3-0
S0DCSEL
R/W
0x0
Sample 0 Digital Comparator Select.
This field has the same encodings as S3DCSEL but is used during
the first sample.