4.2.18 PIOSCSTAT Register (Offset = 0x154) [reset = 0x00400040]
Precision Internal Oscillator Statistics (PIOSCSTAT)
This register provides the user information on the PIOSC calibration. A 32.768-kHz oscillator must be
used as the Hibernation module clock source for the user to calibrate the PIOSC.
PIOSCSTAT is shown in
and described in
.
Return to
Figure 4-24. PIOSCSTAT Register
31
30
29
28
27
26
25
24
RESERVED
R-0x0
23
22
21
20
19
18
17
16
RESERVED
DT
R-0x0
R-0x40
15
14
13
12
11
10
9
8
RESERVED
RESULT
R-0x0
R-0x0
7
6
5
4
3
2
1
0
RESERVED
CT
R-0x0
R-0x40
Table 4-30. PIOSCSTAT Register Field Descriptions
Bit
Field
Type
Reset
Description
31-23
RESERVED
R
0x0
22-16
DT
R
0x40
Default Trim Value.
This field contains the default trim value. This value is loaded into
the PIOSC after every full power up.
15-10
RESERVED
R
0x0
9-8
RESULT
R
0x0
Calibration Result
0x0 = Calibration has not been attempted.
0x1 = The last calibration operation completed to meet 1% accuracy.
0x2 = The last calibration operation failed to meet 1% accuracy.
0x3 = Reserved
7
RESERVED
R
0x0
6-0
CT
R
0x40
Calibration Trim Value.
This field contains the trim value from the last calibration operation.
After factory calibration, CT and DT are the same.