![Texas Instruments SimpleLink Ethernet MSP432E401Y Скачать руководство пользователя страница 1081](http://html1.mh-extra.com/html/texas-instruments/simplelink-ethernet-msp432e401y/simplelink-ethernet-msp432e401y_technical-reference-manual_10955781081.webp)
MII Management (EPHY) Registers
1081
SLAU723A – October 2017 – Revised October 2018
Copyright © 2017–2018, Texas Instruments Incorporated
Ethernet Controller
15.7.26 EPHYBICSR2 Register (Address = 0x1C) [reset = 0x5EE]
Ethernet PHY BIST Control and Status 2 - MR28 (EPHYBICSR2)
This register allows programming the length of the generated packets in bytes for the BIST mechanism
EPHYBICSR2 is shown in
and described in
Return to
Figure 15-114. EPHYBICSR2 Register
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
RESERVED
PKTLENGTH
R-0x0
R/W-0x5EE
Table 15-126. EPHYBICSR2 Register Field Descriptions
Bit
Field
Type
Reset
Description
15-11
RESERVED
R
0x0
10-0
PKTLENGTH
R/W
0x5EE
BIST Packet Length. The value of this register defines the size (in
bytes) of every packet that is generated by the BIST. Default value is
0x5EE, which is equal to 1518 bytes.