ADC Registers
767
SLAU723A – October 2017 – Revised October 2018
Copyright © 2017–2018, Texas Instruments Incorporated
Analog-to-Digital Converter (ADC)
Table 10-35. ADCSSEMUXn Register Field Descriptions (continued)
Bit
Field
Type
Reset
Description
0
EMUX0
R/W
0x0
1st Sample Input Select (Upper Bit).
The EMUX0 field is used during the first sample of a sequence
executed with the sample sequencer.
This bit has the same description as EMUX3.