Table 4-11. DID0 Register Field Descriptions (continued)
Bit
Field
Type
Reset
Description
15-8
MAJOR
R
X
Major Revision.
This field specifies the major revision number of the microcontroller.
The major revision reflects changes to base layers of the design.
The major revision number is indicated in the part number as a letter
(A for first revision, B for second, and so on). This field is encoded
as follows:
0x0 = Revision A (initial device)
0x1 = Revision B (first base layer revision)
0x2 = Revision C (second base layer revision)
... and so on.
7-0
MINOR
R
X
Minor Revision.
This field specifies the minor revision number of the microcontroller.
The minor revision reflects changes to the metal layers of the
design. The MINOR field value is reset when the MAJOR field is
changed. The MINOR field is numeric and is encoded as follows:
0x0 = Initial device, or a major revision update.
0x1 = First metal layer change.