![Texas Instruments SimpleLink Ethernet MSP432E401Y Скачать руководство пользователя страница 733](http://html1.mh-extra.com/html/texas-instruments/simplelink-ethernet-msp432e401y/simplelink-ethernet-msp432e401y_technical-reference-manual_1095578733.webp)
ADC Registers
733
SLAU723A – October 2017 – Revised October 2018
Copyright © 2017–2018, Texas Instruments Incorporated
Analog-to-Digital Converter (ADC)
Table 10-13. ADCEMUX Register Field Descriptions (continued)
Bit
Field
Type
Reset
Description
3-0
EM0
R/W
0x0
SS0 Trigger Select.
This field selects the trigger source for Sample Sequencer 0
0x0 = Reserved
0x1 = Analog Comparator 0. This trigger is configured by the Analog
Comparator Control 0 (ACCTL0) register ().
0x2 = Analog Comparator 1. This trigger is configured by the Analog
Comparator Control 1 (ACCTL1) register ().
0x3 = Analog Comparator 2. This trigger is configured by the Analog
Comparator Control 2 (ACCTL2) register ().
0x4 = External (GPIO Pins). This trigger is connected to the GPIO
interrupt for the corresponding GPIO (see ).
0x5 = Timer. In addition, the trigger must be enabled with the TnOTE
bit in the GPTMCTL register ().
0x6 = PWM generator 0. The PWM generator 0 trigger can be
configured with the PWM0 Interrupt and Trigger Enable
(PWM0INTEN) register ().
0x7 = PWM generator 1. The PWM generator 1 trigger can be
configured with the PWM1INTEN register ().
0x8 = PWM generator 2. The PWM generator 2 trigger can be
configured with the PWM2INTEN register ().
0x9 = PWM generator 3. The PWM generator 3 trigger can be
configured with the PWM3INTEN register ().
0xA = Reserved
0xC = Reserved
0xD = Reserved
0xE = Never Trigger (No triggers are allowed to the ADC digital
interface)
0xF = Always (continuously sample)