![Texas Instruments SimpleLink Ethernet MSP432E401Y Скачать руководство пользователя страница 1164](http://html1.mh-extra.com/html/texas-instruments/simplelink-ethernet-msp432e401y/simplelink-ethernet-msp432e401y_technical-reference-manual_10955781164.webp)
EPI Registers
1164
SLAU723A – October 2017 – Revised October 2018
Copyright © 2017–2018, Texas Instruments Incorporated
External Peripheral Interface (EPI)
Table 16-35. EPIMIS Register Field Descriptions (continued)
Bit
Field
Type
Reset
Description
0
ERRMIS
R
0x0
Error Masked Interrupt Status
0x0 = An error has not occurred or the interrupt is masked.
0x1 = A WFIFO Full, a Read Stalled, or a Timeout error has
occurred and the ERIM bit in the EPIIM register is set, triggering an
interrupt to the interrupt controller.