ADC12_B Operation
877
SLAU367P – October 2012 – Revised April 2020
Copyright © 2012–2020, Texas Instruments Incorporated
ADC12_B
34.2.8 ADC12_B Conversion Modes
shows the four operating modes that are selected by the CONSEQx bits. All state diagrams
assume a 12-bit resolution setting.
Table 34-2. Conversion Mode Summary
ADC12CONSEQx
Mode
Operation
00
Single-channel single-conversion
A single channel is converted once.
01
Sequence-of-channels (autoscan)
A sequence of channels is converted once.
10
Repeat-single-channel
A single channel is converted repeatedly.
11
Repeat-sequence-of-channels (repeated autoscan)
A sequence of channels is converted repeatedly.