ESI Registers
1012
SLAU367P – October 2012 – Revised April 2020
Copyright © 2012–2020, Texas Instruments Incorporated
Extended Scan Interface (ESI)
37.3.19 ESITHR1 Register
ESI PSM Counter Threshold 1 Register
Figure 37-40. ESITHR1 Register
15
14
13
12
11
10
9
8
Threshold1
rw-0
rw-0
rw-0
rw-0
rw-0
rw-0
rw-0
rw-0
7
6
5
4
3
2
1
0
Threshold1
rw-0
rw-0
rw-0
rw-0
rw-0
rw-0
rw-0
rw-0
Table 37-29. ESITHR1 Register Description
Bit
Field
Type
Reset
Description
15-0
Threshold1
RW
0h
Threshold for ESICNT1 counter. The interrupt flag ESIIFG3 is set when
ESICNT1 content and Threshold 1 is equal. (for example, used to detect a
certain increase of ESICNT1)
37.3.20 ESITHR2 Register
ESI PSM Counter Threshold 2 Register
Figure 37-41. ESITHR2 Register
15
14
13
12
11
10
9
8
Threshold2
rw-1
rw-1
rw-1
rw-1
rw-1
rw-1
rw-1
rw-1
7
6
5
4
3
2
1
0
Threshold2
rw-1
rw-1
rw-1
rw-1
rw-1
rw-1
rw-1
rw-1
Table 37-30. ESITHR2 Register Description
Bit
Field
Type
Reset
Description
15-0
Threshold2
RW
FFFFh
Threshold for ESICNT1 counter. The interrupt flag ESIIFG3 is set when
ESICNT1 content and Threshold 2 is equal. (for example, used to detect a
certain decrease of ESICNT1)