
: Feb. 9 2004
1
AR-M550/M620/M700 SIMULATION 8 - 30
Operation/Procedure
1) Select the number corresponding to the target of the operation
check with 10-key.
2) Press [START] key.
The load selected in procedure 1) is operated.
Press [CUSTOM SETTINGS] key to stop the operation.
Operation/Procedure
The operating conditions of the sensors and detectors are displayed.
The active sensors and detectors are highlighted.
Operation/Procedure
1) Select the number corresponding to the target of the operation
check with 10-key.
2) Press [START] key.
The load selected in procedure 1) is operated for 10sec.
Press [CUSTOM SETTINGS] key to stop the operation.
NOTE: Do not execute this simulation with toner in the toner bottle and
the intermediate toner tank. Excessive toner may enter the
developing section, causing overtoner. Check that there is no
toner in the toner bottle and the intermediate toner tank or dis-
assemble the toner motor before executing this simulation.
Operation/Procedure
1) Press [START] key.
The toner motor rotates 2 turns, and the toner presence/empty in
the toner hopper is displayed.
Toner empty: Normal display
Toner remained: Highlighted display
9
9-1
Purpose
Operation test/Check
Function
(Purpose)
Used to check and adjust the operation of the load
(clutch/solenoid) in the duplex section and the control
circuit.
Section
Duplex
Item
Operation
1
ADUM1
ADU motor 1: Upstream
2
ADUM2
ADU motor 2: Downstream
3
DGS
ADU gate solenoid
Press [START] key.
Press [CUSTOM SETTINGS] key to stop
the operations.
9-2
Purpose
Operation test/Check
Function
(Purpose)
Used to check the operations of the sensors and
detectors in the duplex section and its control circuit.
Section
Duplex
Item
Operation
DSW_ADU
ADU cabinet open/close detection
AINPD
ADU paper entry detection
APPD1
ADU transport detection 1
APPD2
ADU transport detection 2
SIMULATION 9-1
ADU OUTPUT CHECK. SELECT 1-3, AND PRESS START.
1. ADUM1
2. ADUM2
3. DGS
1
SIMULATION 9-1
ADU OUTPUT CHECK. EXECUTING···.
1. ADUM1
2. ADUM2
3. DGS
1
SIMULATION 9-2
ADU SENSOR CHECK.
DSW_ADU
AINPD
APPD1 APPD2
10
10-1
Purpose
Operation test/Check
Function
(Purpose)
Used to check the operations of the toner motor and
the related circuit.
Section
Process (Developing)
Item
Operation
TM1
Toner motor 1
TM2
Toner motor 2
Press [START] key.
Press [CUSTOM SETTINGS] key to stop
the operations. Or after 10sec.
10-2
Purpose
Operation test/Check
Function
(Purpose)
Used to check the operations of the toner remaining
quantity sensor and the related circuit.
Section
Process (Developing)
Item
Operation
Press [START] key.
Press [CUSTOM SETTINGS] key to stop the
operation immediately, or after **
SIMULATION 10-1
TONER MOTOR ACTIVATION. SELECT 1-2, AND PRESS START
1. TM1
2. TM2
1
SIMULATION 10-1
TONER MOTOR ACTIVATION. EXECUTING···.
1. TM1
2. TM2
1
SIMULATION 10-2
TONER REST SENSOR CHECK. PRESS START.
TFSD
SIMUL ATION 10-2
TONER REST SENSOR CHECK. EXECUTING···.
TFSD
Содержание AR-M550N
Страница 456: ...Memo ...
Страница 457: ...Memo ...