AR-M550/M620/M700 SIMULATION 8 - 26
Operation/Procedure
1) Select the number corresponding to the target of operation check
with 10-key.
2) Press [START] key.
The load selected in procedure 1 operates.
Press [CUSTOM SETTINGS] key to stop the operation.
*
All fans: All the fans controlled by the engine.
Operation/Procedure
1) Select the number corresponding to the target of operation check
with 10-key.
2) Press [START] key.
The transfer belt performs contact/separation with the OPC drum.
Press [CUSTOM SETTINGS] key to stop the operation.
NOTE: Before disassembling the transfer unit, use this simulation to
separate the transfer unit from the OPC drum.
Press [START] key, and the operation
is started.
Press [CUSTOM SETTINGS] key, and the
operation is stopped immediately or after
repeating the operation several times.
6-2
Purpose
Operation test/Check
Function
(Purpose)
Used to check the operations of each fan motor and its
control circuit.
Section
Other
Item
Operation
1
VFM-EX
Exhaust fan motor (VFM-EX1, 2, 3, VFM-BKL,
VFM-BKU)
2
CFM-UP
Heat exhaust fan motor (Paper exit upper)
(CFM-U1, 2, 3, VFM-BKR)
3
CFM-R
Cooling fan motor (Right side) (CFM-R1, 2, 3)
4
CFM-DC
Cooling fan motor (Power source) (CFM-DC1,
2)
5
CFM-DV
Cooling fan motor (Developing) (CFM-DV)
6
CFM-ICU /HDD
Cooling fan motor (Controller/HDD) (CFM-
ICU/HDD)
7
ALL
All fans control*
8
CFM-AD
Cooling fan motor (paper exit center) (CFM-
U4)
(Exhaust fan motor, heat exhaust fan motor (paper exit upper),
cooling fan motor (right side) cooling fan motor (power source),
cooling fan motor (developing), cooling fan motor (paper exit cen-
ter))
SIMULATION 6-1
FEED OUTPUT CHECK. SELECT 1- 33, AND PRESS START.
1.MSWPR 2.HLPR 3.DCPR 4.MM 5.DM
6.DVM 7.TURM 8.TRM 9.POM1
10.POM2_FW 11.POM2_RV 12.VPM
13.RRC 14.PSBC 15.PSPS 16.T1PFC
17.T2PFC 18.HPFC 19.T1PUS 20.T2PUS
21.HPLS 22.T1LUM 23.T2LUM 24.DSKPFC1
25.DSKPFC2 26.M1PFC 27.M2PFC 28.M1PUS
29.M2PUS 30.M1LUM 31.M2LUM 32.TRC_LCC
33.FUM 34.MPFPUS 35.MPFC 36.MPFGS
2
SIMULATION 6-1
FEED OUTPUT CHECK. EXECUTING···.
1.MSWPR 2.HLPR 3.DCPR 4.MM 5.DM
6.DVM 7.TURM 8.TRM 9.POM1
10.POM2_FW 11.POM2_RV 12.VPM
13.RRC 14.PSBC 15.PSPS 16.T1PFC
17.T2PFC 18.HFC 19.T1PUS 20.T2PUS
21.HPLS 22.T1LUM 23.T2LUM 24.DSKPFC1
25.DSKPFC2 26.M1PFC 27.M2PFC 28.M1PUS
29.M2PUS 30.M1LUM 31.M2LUM 32.TRC_LCC
33.FUM 34.MPFPUS 35.MPFC 36.MPFGS
2
1
1
1
1
1
1
1
1
Press [START] key, and the operation
is started.
Press [CUSTOM SETTINGS] key, and the
operation is stopped.
6-3
Purpose
Operation test/Check
Function
(Purpose)
Used to check the operations of the transfer unit and
the related circuit.
Section
Process (Transfer)
Item
1
TURM (RELEASE)
Transfer unit separation state
2
TURM (JOINT)
Transfer unit contact state
Press [START] key, and the operation is
started.
Press [CUSTOM SETTINGS] key, and the
operation is stopped immediately or after
repeating the operation several times.
After completion
Press [CUSTOM SETTINGS] key to stop the
operation.
SIMULATION 6-2
FAN MOTOR CHECK. SELECT 1-8, CAND PRESS START.
1. VFM-EX 2. CFM-UP
3. CFM-R 4. CFM-DC
5. CFM-DV 6. CFM-ICU /HDD
7. ALL 8. CFM-AD
2
SIMULATION 6-2
FAN MOTOR CHECK..
2. CFM-UP
2
SIMULATION 6-3
TURM CHECK. SELECT 1-2 CAND PRESS START.
1. TURM(RELEASE)
2. TURM(JOINT)
2
SIMULATION 6-3
TURM CHECK. EXECUTING...
1. TURM(RELEASE)
2
SIMULATION 6-3
TURM CHECK.
COMPLETE....