: Feb. 9 2004
1
AR-M550/M620/M700 SIMULATION 8 - 27
Operation/Procedure
1) Select the number corresponding to the operating condition of
aging with 10-key.
The combined mode of 0 - 6 mode and 10, 20, or 30 mode can be
set.
In that case, the number corresponding to one of 0 - 6 mode and
the number corresponding to one of 10, 10, and 30 mode are
added and the sum number is entered.
2) Press [START] key.
The condition selected in procedure 1) is set.
The setting of this simulation is kept valid until the power is turned off.
Operation/Procedure
1) Enter the intermittent aging cycle (unit: sec) with 10-key.
2) Press [START] key.
The time entered in procedure 1) is set.
∗
Set range of interval time: 1 - 999 (sec)
Set the intermittent aging mode cycle of 7-1 with 10-key. (Unit: sec)
Operation/Procedure
1) Select the number corresponding to the warm-up time display
YES/NO.
2) Press [START] key, and the number selected in procedure 1) is
set.
∗
The setting of this simulation is kept valid until the power is turned
off.
The warm-up time is displayed in the unit of second.
Operation/Procedure
1) Enter the number corresponding to the adjustment item with 10-
key.
2) Press [START] key.
3) Enter the adjustment value with 10-key.
4) Press [START] key.
(The set value is stored, and the output corresponding to the set
value is outputted for 30sec.)
Press [CUSTOM SETTINGS] key to stop the operation.
(The developing bias output voltage adjustment and output check can
be made in each print mode.)
7
7-1
Purpose
Setting
Function
(Purpose)
Used to set the operating conditions of aging.
Section
Item
Operation
0
NO MISS FEED DETECTION
No jam detection
1
AGING
Aging mode
2
AGING/NO MISS FEED
DETECTION.
No jam detection, aging
mode
3
AGING/NO MISS FEED
DETECTION/NO WARM UP/
NO TEMPERATURE
CONTROL.
No jam detection/ no warm-
up/ no fusing temperature
control, aging mode
4
NO WARM UP.
No warm-up
5
AGING/INTERVAL.
Intermittent aging mode
6
AGING/INTERVAL/NO MISS
FEED DETECTION.
No jam detection
intermittent aging mode
+10
NO PROCESS UNIT CHECK.
Above +10: No process unit
(including the developing
unit) detection
+20
NO SHADING.
Above +20: No shading
+30
NO PROCESS UNIT CHECK/
NO SHADING.
Above +30: No process unit
detection /no shading
Press [START] key to start registration and operation.
The operation mode is kept until the power is turned off or setting is made again.
7-6
Purpose
Setting
Function
(Purpose)
Used to set the intermittent aging cycle.
Section
Item
Operation
SIMULATION 7-1
AGING TEST SETTING. SELECT 0-36, AND PRESS START.
0.NO MISS FEED DETECTION
1.AGING
2.AGING/NO MISS FEED DETECTION.
3.AGING/NO MISS FEED DETECTION/
NO WARM UP/NO TEMPERATURE CONTROL.
4.NO WARM UP.
5.AGING/INTERVAL.
6.AGING/INTERVAL/NO MISS FEED DETECTION.
+10:NO PROCESS UNIT CHECK.
+20:NO SHADING.
+30:NO PROCESS UNIT CHECK/NO SHADING.
2
7-8
Purpose
Setting
Function
(Purpose)
Used to set the warm-up time display YES/NO.
Item
Operation
Warm-up is completed.
Press [CUSTOM SETTINGS] key.
8
8-1
Purpose
Adjustment/Operation test/Check
Function
(Purpose)
Used to check and adjust the operations of the
developing voltage of each color and the control circuit.
Section
Image process (Photoconductor/Developing/Transfer/
Cleaning)
SIMULATION 7-6
INTERVAL AGING CYCLE SETUP. INPUT TIME AND PRESS START.
(1-999, UNIT: sec)
10
SIMULATION 7-8
WARM UP TIME DISPLAY.
ARE YOU SURE?
1. YES
2. NO
1
Press [START] key,
and time count is started.
SIMULATION 7-8
WARM UP TIME DISPLAY. WARMING UP,PLEASE WAIT.
(UNIT:sec)
30
Press [CUSTOME SETTING] key,
and time count is stopped.
SIMULATION 7-8
WARM UP TIME DISPLAY. WARM UP COMPLETED.
(UNIT:sec)
60