![R&S RTA4000 Скачать руководство пользователя страница 158](http://html2.mh-extra.com/html/rands/rta4000/rta4000_user-manual_3161987158.webp)
Measurements
R&S
®
RTA4000
158
User Manual 1335.7898.02 ─ 08
Figure 8-4: Left: menu for delay measurement, right: menu for delay to trigger measurement
Measure Source
Selects the rising or falling edge for the indicated source.
Remote command:
Mode for Measure Source, delay measurement
Defines the first edge for the delay measurement.
"Nearest"
Nearest edge to the trigger point.
"Forward"
First edge from the left window edge.
"Backward"
First edge from the right window edge, which is the last edge if coun-
ted from the left window edge.
Remote command:
MEASurement<m>:DELay:DIRection
Mode for Measure Source 2, delay measurement
Defines the second edge for the delay measurement.
"Nearest"
Nearest edge to the edge determined on "Measure Source".
"Forward"
Next edge to the right, counted from the edge determined on "Mea-
sure Source".
"Backward"
Next edge to the left, counted from the edge determined on "Measure
Source".
Remote command:
MEASurement<m>:DELay:DIRection
Mode, delay to trigger measurement
Sets the direction in which the measured edge is detected.
"Nearest"
Nearest edge to the trigger point.
"Forward"
Next edge from the trigger to the right.
"Backward"
Next edge from the trigger to the left.
Automatic measurements