![R&S RTA4000 Скачать руководство пользователя страница 142](http://html2.mh-extra.com/html/rands/rta4000/rta4000_user-manual_3161987142.webp)
Waveform analysis
R&S
®
RTA4000
142
User Manual 1335.7898.02 ─ 08
"Rising"
Only positive clock edges are considered.
"Falling"
Only negative clock edges are considered.
"Either"
The clock edges next to the data edge are considered regardless of
the clock slope. Use this setting, for example, for signals with double
data rate.
Remote command:
SEARch:TRIGger:DATatoclock:CEDGe
Setup Time
Sets the minimum time
before
the clock edge while the data signal must stay steady
above or below the data level.
Remote command:
SEARch:TRIGger:DATatoclock:STIMe
Hold Time
Sets the minimum time
after
the clock edge while the data signal must stay steady
above or below the data level.
Remote command:
SEARch:TRIGger:DATatoclock:HTIMe
7.5.9
Pattern search
For pattern search, up to four analog channels can be used as source. If MSO option
R&S
RTA-B1 is installed, also digital channels can be included in the pattern. For each
channel, you define the state. The states are combined logically, and the time of true
pattern results is compared with a specified time range. Thus you can find state transi-
tions inside or outside this time range.
► Select [Search] > "Search Type" = "Pattern" > "Setup".
Search