WGENerator:VOLTage:OFFSet
<Offset>
Sets the DC offset of the selected generator function.
Parameters:
<Offset>
Numeric value
Range:
-3.00 to 3.00
*RST:
0.00E+00
Default unit: V
WGENerator:FREQuency
<Frequency>
Defines the frequency.
Parameters:
<Frequency>
Range:
Depends on the selected function. For details, refer
to the datasheet.
*RST:
10 kHz
WGENerator:FUNCtion:PULSe:DCYCle
<DutyCycle>
Defines the duty cycle value of the generator function pulse.
Parameters:
<DutyCycle>
Numeric value
Range:
1.000E+01 to 9.000E+01
*RST:
2.500E+01
Default unit: %
WGENerator:TRIangle:SYMMetry
<Symmetry>
Sets the symmetry for the triangle waveform.
Parameters:
<Symmetry>
50% defines symmetric triangles. Values <50% define triangles
with steeper rising edge leaned to the left. Values >50% define
triangles with steeper falling edge leaned to the right.
Range:
1 to 99
Increment: 1
*RST:
50
Default unit: %
WGENerator:FUNCtion:PULSe:ETIMe
<EdgeTime>
Sets the pulse edge time.
Parameters:
<EdgeTime>
Signal generation (option R&S
RTA-B6)