<n>
*
Selects the frame.
<o>
*
Selects the word number.
Return values:
<StopTime>
Range:
depends on sample rate, record length, and time
base
Increment: depends on the time base
Default unit: s
Usage:
Query only
BUS<b>:SPI:FRAME<n>:WORD<o>:MOSI?
Returns the data value of the specified word on the MOSI line.
Use this command if only one line is defined.
Suffix:
<b>
.
1..4
<n>
*
Selects the frame (1...n)
<o>
*
Selects the word number (1...o)
Return values:
<Data>
Decimal value of the data word
Usage:
Query only
BUS<b>:SPI:FRAME<n>:WORD<o>:MISO?
Returns the data value of the specified word on the optional MISO line.
Suffix:
<b>
.
1..4
<n>
*
Selects the frame (1...n)
<o>
*
Selects the word number (1...o)
Return values:
<Data>
Decimal value of the data word
Usage:
Query only
Serial bus analysis