The trigger "Hold
Off" defines when the next trigger event is recognized after the cur-
rent trigger event. Thus, it affects the next trigger to occur after the current one. Hold
off helps to obtain stable triggering when the oscilloscope is triggering on undesired
events.
Remote command:
Actions on Trigger, Configuration
Enables and select the actions to be done on trigger event. for details, see
ter 6.12, "Actions on trigger"
6.4
Edge trigger
The edge trigger is the most common trigger type. The trigger occurs when the signal
from the trigger source passes the trigger level in the specified direction (slope).
Figure 6-1: Edge trigger event with positive slope (rising edge)
► [Trigger] > "Trigger Type" = "Edge"
Edge trigger