![R&S RTA4000 Скачать руководство пользователя страница 675](http://html2.mh-extra.com/html/rands/rta4000/rta4000_user-manual_3161987675.webp)
Remote control commands
R&S
®
RTA4000
675
User Manual 1335.7898.02 ─ 08
EQUal | NEQual | GTHan | LTHan
Equal, not equal, greater than, less than. These conditions
require one data word to be set with
TRIGger:A:I2S:CHANnel:TDM<n>:DMAX
<MaximumValue>
Specifies the maximum data value to be found, if
is set to
INRange
or
OORange
Parameters:
<MaximumValue>
The data format is decimal. The maximum value is limited by the
word length. Consider that audio words are signed numbers in
2's complement format. For example, an 8-bit data word has a
value range from -128 to 127.
TRIGger:A:I2S:CHANnel:TDM<n>:DMIN
<MinimumValue>
Specifies a data pattern, or sets the the start value of a data pattern range.
Parameters:
<MinimumValue>
TRIGger:A:I2S:FUNCtion
<Function>
Sets the logical combination to trigger on data words on different channels. The instru-
ment triggers if all conditions are met inside one frame.
The setting is relevant, if
DATA
or
WINDow
.
Parameters:
<Function>
AND | OR
TRIGger:A:I2S:TYPE
<TriggerMode>
Specifies the trigger mode for audio signals.
Parameters:
<TriggerMode>
DATA | WINDow | WSELect | ERRCondition
DATA
Triggers on a data word or a data range that occurs on a speci-
fied channel. You can also trigger on an AND combination of
data conditions on different channels.
Use the
TRIGger:A:I2S:CHANnel:LEFT:CONDition
mands to define the data condition.
To set the logical combination to trigger on data words on differ-
ent channels, use
Serial bus analysis