![R&S RTA4000 Скачать руководство пользователя страница 483](http://html2.mh-extra.com/html/rands/rta4000/rta4000_user-manual_3161987483.webp)
Remote control commands
R&S
®
RTA4000
483
User Manual 1335.7898.02 ─ 08
Parameters:
<DoublePulseEnable>ON | OFF
CALCulate:MATH<m>:TRACk:THReshold:HYSTeresis
<Hysteresis>
Sets the hysteresis for correct edge detection.
Suffix:
<m>
.
1..5
Parameters:
<Hysteresis>
Default unit: V
CALCulate:MATH<m>:TRACk:THReshold[:UPPer]
<ThresholdLevel>
Sets the threshold for unipolar track sources, or the upper level for bipolar sources.
The signal is measured at the crossing points of the signal with the threshold.
Suffix:
<m>
.
1..5
Parameters:
<ThresholdLevel>
Default unit: V
CALCulate:MATH<m>:TRACk:THReshold:LOWer
<ThresholdLevel>
Sets the lower level for bipolar track sources, which determines the crossing points on
negative pulses.
Suffix:
<m>
.
1..5
Parameters:
<ThresholdLevel>
Default unit: V
17.6.3
Reference waveforms
In all REFCurve:... commands, the suffix <m> selects the reference waveform.
To get the waveform data, use the following commands:
●
●
●
●
●
●
●
Waveform analysis