Compare
Defines the operator for comparison of the decoded data word with the specified data
word.
The following operators can be set: equal, not equal, greater than, lower than, in range
and out of range.
If the data on the selected channel is not relevant for the trigger condition, select "Don't
care".
The setting is relevant for data and window trigger types.
Remote command:
TRIGger:A:I2S:CHANnel:LEFT:CONDition
TRIGger:A:I2S:CHANnel:RIGHt:CONDition
TRIGger:A:I2S:CHANnel:TDM<n>:CONDition
Data / Data Min. / Data Max.
Define the data words to be compared with the decoded data word. The data format is
decimal. The maximum value is limited by the word length. Consider that audio words
are signed numbers in 2's complement format. For example, an 8-bit data word has a
value range from -128 to 127.
The setting is relevant for trigger types data and window.
Remote command:
TRIGger:A:I2S:CHANnel:LEFT:DMAX
TRIGger:A:I2S:CHANnel:LEFT:DMIN
TRIGger:A:I2S:CHANnel:RIGHt:DMAX
TRIGger:A:I2S:CHANnel:RIGHt:DMIN
TRIGger:A:I2S:CHANnel:TDM<n>:DMAX
TRIGger:A:I2S:CHANnel:TDM<n>:DMIN
Combination
Sets the logical combination to trigger on data words on different channels. The instru-
ment triggers if all conditions are met inside one frame.
"And": the instrument triggers if the data conditions on all selected channels are fulfil-
led.
"Or": The instrument triggers if one of the specified data conditions is fulfilled.
The setting is relevant for trigger types data and window.
Remote command:
Window Length
Sets the number of subsequent frames (audio samples) for which the data conditions
are fulfilled.
Remote command:
Word Select
Sets the rising("Positive") or falling ("Negative") edge of the word select signal as trig-
ger condition.