8-3
Section
Setting Data for Memory Operation
177
8-3-2 Axis Parameter Area
Item
Axis parameter area
Bits
Contents
NC1
j
3 NC2
j
3
NC4
j
3
X axis
Y axis
Z axis
U axis
I/O settings
m+4
m+32
m+60
m+88
04 to 06
08
03
Limit input signal type
0: N.C. input; 1: N.O. input
Origin proximity input signal ty
0: N.C. input; 1: N.O. input
Origin proximity input signal ty
0: N.C. input; 1: N.O. input
Operation mode
Origin search
operation
Origin detection
method
Origin search
direction
m+5
m+33
m+61
m+89
00 to 03
04 to 07
08 to 11
12 to 15
15
00
Operation mode
0 to 3: Modes 0 to 3
Origin search operation
0: Reversal mode 1
1: Reversal mode 2
2: Single-direction mode
Origin detection method
0: With origin proximity
input signal reversal
1: Without origin proxim
input signal reversal
2: Origin proximity input
signal not used
3: Limit input signal use
instead of origin
proximity input signal
Origin search direction:
0: CW; 1: CCW.
Initial speed
m+8
m+9
m+36
m+37
m+64
m+65
m+92
m+93
00 to 15
(Rightmost)
00 to 15
(Leftmost)
15
00
Leftmost
15
00
Rightmost
Setting range:
0 to 7A120 Hex
(0 to 500,000 pps)
Acceleration time m+20
m+21
m+48
m+49
m+76
m+77
m+104
m+105
00 to 15
(Rightmost)
00 to 15
(Leftmost)
15
00
Leftmost
15
00
Rightmost
Setting range:
0 to 3D090 Hex
Deceleration time m+22
m+23
m+50
m+51
m+78
m+79
m+106
m+107
00 to 15
(Rightmost)
00 to 15
(Leftmost)
0 to 3D090 Hex
(0 to 250,000 ms)