![Omron CS1W-NC113 - REV 02-2008 Скачать руководство пользователя страница 215](http://html1.mh-extra.com/html/omron/cs1w-nc113-rev-02-2008/cs1w-nc113-rev-02-2008_manual_742370215.webp)
9-1
Section
Jogging
205
9-1
Jogging
This section describes the JOG operation and the data needed for performing it.
9-1-1 Outline of Operation
While JOG is ON, axis operation is started using the designated direction,
speed, and acceleration time. When it is turned OFF, positioning decelerates
with the designated deceleration time and then stops. The JOG operation can be
executed even when the origin has not been established.
9-1-2 Procedure for Executing JOG
1, 2, 3...
1. Set the operating data area using the parameters.
2. Set the speed and acceleration/deceleration times in the operating data
area.
3. Designate the start direction in the operating memory area.
4. Turn ON the JOG Bit. If the initial speed is set in the parameters, it will be in
effect.
9-1-3 Beginning Words of Operating Memory Area, Operating Data Area,
and Parameter Areas
The beginning words of the operating memory area, operating data area, and
common parameter area used for a Position Control Unit (PCU) are determined
(or set) according to the following.
•
Beginning word of the operating memory area, n = CIO 2000 + 10
×
unit num-
ber
•
Beginning word of the common parameter area, m = 100
×
unit num-
ber
•
Beginning word of the operating data area, l, is specified in m and m+1.
Set the beginning words of the operating data area and designate the axis
parameters used with the common parameters as shown below.
Word
Name
Bit
Reference
m
Operating data
area designation
00 to 15
Section 4
m+1
Beginning word of
operating data
area
00 to 15
m+2
Axis parameter
designation
00 to 15
9-1-4 Operating Memory Area Allocation and Operating Data Area
Settings
Operating Memory Area
Name
Model
Operating memory area
Bit
Details
X
axis
Y
axis
Z
axis
U
axis
JOG
NC4
j
3
n
n+2
n+4
n+6
09
1: Execute JOG; 0: Stop
Direction
designation
NC2
j
3
NC1
j
3
n
n
n+2
10
1: CCW direction; 0: CW direction
Busy Flag
NC4
j
3
NC2
j
3
NC1
j
3
n+8
n+4
n+2
n+11
n+7
n+14
n+17
13
1: Busy