![Omron CS1W-NC113 - REV 02-2008 Скачать руководство пользователя страница 111](http://html1.mh-extra.com/html/omron/cs1w-nc113-rev-02-2008/cs1w-nc113-rev-02-2008_manual_742370111.webp)
5-1
Section
Transferring and Saving Data
99
Address
C200HW-NC1
j
3
C200HW-NC2
j
3
C200HW-NC4
j
3
0004 to 0073
Axis parameters (one axis)
Axis parameters (two axes)
Axis parameters (four axes)
1000 to 112B
For X
Axis
Positioning
sequences
For X
Axis
Positioning
sequences
For X
Axis
Positioning
sequences
112C to 11F3
s
Speeds
s
Speeds
s
Speeds
11F4 to 12BB
Positions
Positions
Positions
12BC to 12CF
Acceleration times
Acceleration times
Acceleration times
12D0 to 12E3
Deceleration times
Deceleration times
Deceleration times
12E4 to 12F7
Dwell times
Dwell times
Dwell times
12F8 to 1303
Zones
Zones
Zones
2000 to 212B
For Y
Axis
Positioning
sequences
For Y
Axis
Positioning
sequences
212C to 21F3
s
Speeds
s
Speeds
21F4 to 22BB
Positions
Positions
22BC to 22CF
Acceleration times
Acceleration times
22D0 to 22E3
Deceleration times
Deceleration times
22E4 to 22F7
Dwell times
Dwell times
22F8 to 2303
Zones
Zones
3000 to 312B
For Z
Axis
Positioning
sequences
312C to 31F3
s
Speeds
31F4 to 32BB
Positions
32BC to 32CF
Acceleration times
32D0 to 32E3
Deceleration times
32E4 to 32F7
Dwell times
32F8 to 3303
Zones
4000 to 412B
For U
Axis
Positioning
sequences
412C to 41F3
s
Speeds
41F4 to 42BB
Positions
42BC to 42CF
Acceleration times
42D0 to 42E3
Deceleration times
42E4 to 42F7
Dwell times
42F8 to 4303
Zones
5-1-5 Data Checking
1, 2, 3...
1. When data is transferred (written) to the PCU, it is first copied to the PCU’s
internal receive buffer.
2. A check is then performed on all of the values in the receive buffer.
3. If a checked value is within the acceptable range, it is written to the appropri-
ate parameter or data area.
If a value is found to be outside the acceptable range, the appropriate error
code (in the range 1000 to 4019) is output to the operating memory area
and, at the same time, all of the data in the buffer is annulled. (In this case,
the transferred parameter or data is not written to its respective parameter or
data area.)
Содержание CS1W-NC113 - REV 02-2008
Страница 1: ...CS1W NC113 213 413 133 233 433 Position Control Units ...
Страница 2: ...iv ...
Страница 4: ...vi ...