![Omron CS1W-NC113 - REV 02-2008 Скачать руководство пользователя страница 280](http://html1.mh-extra.com/html/omron/cs1w-nc113-rev-02-2008/cs1w-nc113-rev-02-2008_manual_742370280.webp)
10-7
Section
Transferring and Saving Data
270
Data Memory Settings
DM
Setting
Contents of setting
D20000
000D
Sets the operating data area to D00500 onwards.
D20001
01F4
p
g
D20002
0000
Parameters read from PCU’s internal flash memory.
The parameters for each axis are read from the flash memory of the PCU. Trans-
fer them in advance to the PCU and then save them.
WRITE DATA and SAVE DATA
DM
Setting
Contents of setting
D20200
000D
Set the operating data area to D00600 onwards.
D20201
0258
p
g
D20202
0000
Parameters read from PCU’s internal flash memory.
Designation of the Operating Data Area
The operating data area is set during programming and therefore no setting is
necessary beforehand.
Data Settings
READ DATA
•
Axis Parameters
•
Positioning Sequences
•
Speeds
•
Positions
•
Acceleration and Deceleration Times
•
Dwell Times
•
Zones
Transfer the data needed for the operation beforehand to the PCU for both the X
and Y axes, and save it in the flash memory.
The data in D03000 through D03799 is transferred to the PCU, so set all the data
such as the axis parameters, positioning sequences, speeds and so on, in this
DM Area.