![Omron CS1W-NC113 - REV 02-2008 Скачать руководство пользователя страница 216](http://html1.mh-extra.com/html/omron/cs1w-nc113-rev-02-2008/cs1w-nc113-rev-02-2008_manual_742370216.webp)
9-2
Section
Teaching
206
If the software limit has been disabled (CW limit equal to or less than CCW limit)
by the axis parameters, even if JOG is executed with the origin established, the
result will be the same as if the origin were not established. The present position
becomes “0” when operation starts.
Operating Data Area
Name
Model
Operating data area
Bit
Details
X
axis
Y
axis
Z
axis
U
axis
Speed
NC4
j
3
NC2
j
3
NC1
j
3
I+10
I+11
I+10
I+11
I+10
I+11
I+22
I+23
I+22
I+23
I+34
I+35
I+46
I+47
00 to 15
(rightmost)
00 to 15
(leftmost)
15
00
Leftmost
15
00
Rightmost
Setting range:
1 to 7A120 Hex
(1 to 500,000 pps)
Acceleration
time
NC4
j
3
NC2
j
3
NC1
j
3
I+12
I+13
I+12
I+13
I+12
I+13
I+24
I+25
I+24
I+25
I+36
I+37
I+48
I+49
00 to 15
(rightmost)
00 to 15
(leftmost)
15
00
Leftmost
15
00
Rightmost
Setting range:
0 to 3D090 Hex
(0 to 250,000 ms)
Deceleration
time
NC4
j
3
NC2
j
3
NC1
j
3
I+14
I+15
I+14
I+15
I+14
I+15
I+26
I+27
I+26
I+27
I+38
I+39
I+50
I+51
00 to 15
(rightmost)
00 to 15
(leftmost)
If speed is changed during a JOG operation the operation will be carried out
using the changed data. If the acceleration/deceleration time number is
changed, the changes will be effective with the next JOG command.
9-1-5 Timing Chart
The following is an example of a timing chart for a JOG operation on the X axis
with a 4-axis PCU.
Directional speed
(word n, bit 10)
JOG
(word n, bit 09)
Speed
Acceleration
Initial speed
Target speed
Deceleration
Pulse output
Busy Flag
(word, n+8, bit 13)
9-2
Teaching
This section describes the teaching operation and the data needed for perform-
ing it.
9-2-1 Outline of Operation
The present position is taken as the designated position number (teaching
address). The position data is taken in when TEACH is turned ON.
Note
Before executing TEACH, first establish the origin. If the origin is not first estab-
lished, a present position unknown error (error code 5040) will be generated.
Содержание CS1W-NC113 - REV 02-2008
Страница 1: ...CS1W NC113 213 413 133 233 433 Position Control Units ...
Страница 2: ...iv ...
Страница 4: ...vi ...