![Omron CS1W-NC113 - REV 02-2008 Скачать руководство пользователя страница 184](http://html1.mh-extra.com/html/omron/cs1w-nc113-rev-02-2008/cs1w-nc113-rev-02-2008_manual_742370184.webp)
8-1
Section
Outline
174
Model
Word
Bit
Name
X axis
Y axis
Z axis
U axis
NC4
j
3
NC2
j
3
n+8
n+4
n+11
n+7
n+14
n+17
04
Waiting For Memory
Operation Flag
NC2
j
3
NC1
j
3
n+4
n+2
n+7
05
Positioning Completed
Flag
11
Teaching Completed
Flag
12
Error Flag (See note)
14
Data Transferring Flag
(X axis only)
Operating Data Area
Model
Word
Bit
Name
X axis
Y axis
Z axis
U axis
NC4
j
3
NC2
j
3
NC1
j
3
n+59
n+35
n+23
n+63
n+39
n+67
n+71
00 to 15 Output code
Operating Memory Area
Model
Word
Bit
Name
X axis
Y axis
Z axis
U axis
NC4
j
3 n+8
n+11
n+14
n+17
06
No Origin Flag
j
NC2
j
3 n+4
n+7
07
Origin Stop Flag
NC2
j
3
NC1
j
3
n+4
n+2
n+7
08
Zone 0 Monitor Flag
NC1
j
3 n+2
09
Zone 1 Monitor Flag
10
Zone 2 Monitor Flag
12
Error Flag (See note)
13
Busy Flag
15
Deceleration Stop
Execution Flag
Operating Data Area
Model
Word
Bit
Name
X axis
Y axis
Z axis
U axis
NC4
j
3
NC2
j
3
NC1
j
3
n+56
n+57
n+32
n+33
n+20
n+21
n+60
n+61
n+36
n+37
n+64
n+65
n+68
n+69
00 to 15
00 to 15
Present position (rightmost)
Present position (leftmost)
Note
The Error Flag is input for either the starting axis or the designated axis, depend-
ing on the type of error.
In the following example, the Y axis is specified by the axis designation when
starting from the X axis.
PCU Model:
CS1W-NC413
Sequence #0 (X)
Designated Axis