NAVIS NavDP 4000. Operation Manual
Figure 7.16: LOG details
or absolute velocity of the vessel
– Vgx
– Vgy
Processing result is current velocity.
The following graphs are provided for LOG (Figure 7.17):
Figure 7.17: LOG Trend view
7.3.5
Draft Details
7.3.5.1
Draft Sensor detailed data
In general, draft/load sensor measures ship draft in several points and/or mean draft and loading/displacement values.
Detailed data includes:
– Sensor softkey with indicators
– Ship contour with marked measurement points (if any)
– Draft measurements in specified points – raw data (if they are measured by sensor)
– Mean draft value (calculated or measured by sensor)
– Loading/displacement value (if it measured by sensor)
Processing results include:
– Mean draft (estimated or measured by sensor)
– Displacement (calculated by mean draft or measured by sensor)
– Loading (calculated by mean draft or measured by sensor)
135
Doc. 000.JDP-10000-OME, rev.3.3.13/“2102.$–17A-Advanced”
Содержание NavDP 4000 Series
Страница 88: ...NAVIS NavDP 4000 Operation Manual Figure 5 35 Dark Theme 87 Doc 000 JDP 10000 OME rev 3 3 13 2102 17A Advanced...
Страница 222: ...NAVIS NavDP 4000 Operation Manual Figure 10 74 Drift Plot Window 221 Doc 000 JDP 10000 OME rev 3 3 13 2102 17A Advanced...
Страница 324: ...NAVIS NavDP 4000 Operation Manual Figure H 4 Remote DLS Mode 323 Doc 000 JDP 10000 OME rev 3 3 13 2102 17A Advanced...