System Functions
NOTE!
Drift analysis is performed in DP control mode only. Otherwise, zero
values are displayed for the cross time and heading.
Figure 10.75: Drift Plot View without Vessel’s Drift
Selection of Hypothetic Power and Thruster Configuration
A list of the DP system components (thrusters, power components, bus tie breakers) is displayed in the bottom of the
Drift Analysis window (see Figure 10.74), so that different power and thrusters configurations can be investigated. Each
component can be activated and deactivated.
Round indicator
shows status of each component.
Green
color means:
– for the thruster: it is activated;
– for the power component: it is activated;
– for bus tie breaker: it is closed.
Red
color means:
– for the thruster: it is deactivated;
– for the power component: it is deactivated;
– for bus tie breaker: it is open.
Power limits for power components and thrust limits for the thrusters in percent, or position On/Off for tie breakers are
displayed to the right of the component name. In case the component is deactivated, the dashes are displayed instead of
values for power/thrust limits.
Doc. 000.JDP-10000-OME, rev.3.3.13/“2102.$–17A-Advanced”
222
Содержание NavDP 4000 Series
Страница 88: ...NAVIS NavDP 4000 Operation Manual Figure 5 35 Dark Theme 87 Doc 000 JDP 10000 OME rev 3 3 13 2102 17A Advanced...
Страница 222: ...NAVIS NavDP 4000 Operation Manual Figure 10 74 Drift Plot Window 221 Doc 000 JDP 10000 OME rev 3 3 13 2102 17A Advanced...
Страница 324: ...NAVIS NavDP 4000 Operation Manual Figure H 4 Remote DLS Mode 323 Doc 000 JDP 10000 OME rev 3 3 13 2102 17A Advanced...