Control Modes
Figure 9.2: ROT Heading mode
NOTE!
The desired rate of turn will not be provided if there would not be
enough available thrust (or power), or the demand is very big.
9.2.3
Auto Heading
The vessel motion in Auto Heading mode is shown in Figure 9.3.
Figure 9.3: Auto Heading mode
This mode can be activated using
AUTO
softkey at in the
HDG
panel, Mode/Function Panel.
This heading control mode can be combined with any position control mode.
The rotational moment demand is calculated by the controller. During the operation operator can change heading
setpoint.
When changing heading by the control panel’s knob, the clockwise or counterclockwise direction of preset heading
adjustment determines the vessel’s turn direction. In case of entering from dialog window the letter
P
or
S
determines the
direction of turn.
Following options can be used in this mode:
Change Heading Setopint (Preset Heading, Offset Heading)
Remote COR position (COR in bow, stern, or other specified point)
Doc. 000.JDP-10000-OME, rev.3.3.13/“2102.$–17A-Advanced”