Switching On/Off and Troubleshooting
3.6.1
Basic way
The Mode Selector is assumed to be in the
OFF
position.
Press the POWER pushbutton installed in the corresponding Control Unit and hold it for 2 seconds until it starts blink-
ing. Then the control system will be completely switched off in 3 minutes until the power pushbutton stops blinking.
3.6.2
Supplementary Way
The Mode Selector is assumed to be in the
OFF
position.
Exit the current operational mode using the Exit softkey
on the Operator Interface Screen (in the upper left corner).
Select
Shut Down
option on the Main Screen.
Computer
for control computer switching off
System
for the DP system closing
Press the “
<
” symbol at the menu title to back to the main screen.
NOTE!
The switching off process for multi-WS configuration is described in
the Section 3.2, page 51
You can also resort to the emergency way, however, in an emergency situation only.
3.6.3
Emergency method
This method is intended for the system shutdown regardless the
Mode Selector
position.
Press the
Power
pushbutton installed in the corresponding Control Unit and hold it for 10 seconds. Then the control
system will be switched off in 3 minutes.
While the control system is shutting down, “Power” indicator at control panel is blinking and the following inscription
is being displayed on the LCD:
SYSTEM IS AUTOMATICALLY SHUTTING DOWN
POWER OFF REQUEST RECEIVED
Doc. 000.JDP-10000-OME, rev.3.3.13/“2102.$–17A-Advanced”