M800/M80/E80/C80 Series Alarm/Parameter Manual
1 Operation Errors (M)
22
IB-1501279-H
Details
The spatial error compensation option is not available.
Remedy
Check the specifications.
Details
The compensation amount is outside the setting range.
Due to the calculation of the excessive amount, it is clamped by +/-1mm.
Remedy
Set the compensation amount within the setting range.
Details
A measurement condition adjustment or backlash adjustment was attempted to an axis with which auto-
matic backlash adjustment is impossible.
A measurement condition adjustment or backlash adjustment was attempted even though all the axes had
not reached the 1st reference position.
The operation mode is other than memory mode.
The slave axis of synchronous control is selected as adjustment axis.
An attempt has been made to start an adjustment by cycle start.
Remedy
Check the adjustment axis.
Start the adjustment after all the axes return to the 1st reference position.
Check the operation mode.
Select the master axis of synchronous control as adjustment axis when adjusting the slave axis.
Start the adjustment by automatic backlash adjustment start signal.
Details
An illegal operation was attempted during measurement condition adjustment or backlash adjustment.
Remedy
Continue the operation after canceling the measurement condition adjustment and backlash adjustment.
Details
The APLC authentication password is inconsistent.
Remedy
Contact the machine tool builder.
Details
The drive unit's hardware or software does not conform to the high-cycle sampling mode.
High-cycle data are not used even when high-cycle sampling has been set.
High-cycle sampling was attempted while the axis targeted for high-cycle sampling was moving.
High-cycle sampling was attempted during speed monitor mode.
High-cycle sampling was attempted while any of the following operations is being executed: Dog-type zero
point return, absolute position setting, synchronous tapping, spindle synchronization, hobbing, tool spindle
synchronization IC.
Remedy
The software or hardware does not conform to the function. Contact service center.
Set data for high-cycle sampling.
Execute high-cycle sampling after stopping the axis targeted for high-cycle sampling.
Execute high-cycle sampling after cancelling the speed monitor mode.
Execute high-cycle sampling after stopping the currently executed functions.
M01
No spec: Spatial error comp
0260
M01
Spatial error comp excessive
0261
M01
Auto backlash adjust illegal
0270
M01
Operating auto backlash adjust
0271
M01
APLC password mismatch
0280
M01
High-cycle sampling disabled
0290
Содержание C80 Series
Страница 1: ......
Страница 7: ......
Страница 11: ......
Страница 13: ......
Страница 15: ......
Страница 18: ...1 IB 1501279 H Alarm ...
Страница 19: ...M800 M80 E80 C80 Series Alarm Parameter Manual 2 IB 1501279 H ...
Страница 20: ...1 3 IB 1501279 H Operation Errors M ...
Страница 54: ...2 37 IB 1501279 H Stop Codes T ...
Страница 62: ...3 45 IB 1501279 H Servo Spindle Alarms S ...
Страница 81: ...M800 M80 E80 C80 Series Alarm Parameter Manual 3 Servo Spindle Alarms S 64 IB 1501279 H ...
Страница 82: ...4 65 IB 1501279 H MCP Alarms Y ...
Страница 98: ...5 81 IB 1501279 H System Alarms Z ...
Страница 111: ...M800 M80 E80 C80 Series Alarm Parameter Manual 5 System Alarms Z 94 IB 1501279 H ...
Страница 112: ...6 95 IB 1501279 H Absolute Position Detection System Alarms Z7 ...
Страница 117: ...M800 M80 E80 C80 Series Alarm Parameter Manual 6 Absolute Position Detection System Alarms Z7 100 IB 1501279 H ...
Страница 118: ...7 101 IB 1501279 H Distance coded Reference Scale Errors Z8 ...
Страница 120: ...8 103 IB 1501279 H Emergency Stop Alarms EMG ...
Страница 124: ...9 107 IB 1501279 H Computer Link Errors L ...
Страница 126: ...10 109 IB 1501279 H User PLC Alarms U ...
Страница 136: ...11 119 IB 1501279 H Network Service Errors N ...
Страница 139: ...M800 M80 E80 C80 Series Alarm Parameter Manual 11 Network Service Errors N 122 IB 1501279 H ...
Страница 140: ...12 123 IB 1501279 H Program Errors P ...
Страница 178: ...13 161 IB 1501279 H Smart Safety Observation Alarm V ...
Страница 192: ...14 175 IB 1501279 H Multi CPU Errors A C80 ...
Страница 215: ...M800 M80 E80 C80 Series Alarm Parameter Manual 14 Multi CPU Errors A C80 198 IB 1501279 H ...
Страница 216: ...199 IB 1501279 H Parameter ...
Страница 217: ...M800 M80 E80 C80 Series Alarm Parameter Manual 200 IB 1501279 H ...
Страница 218: ...15 201 IB 1501279 H User Parameters ...
Страница 359: ...M800 M80 E80 C80 Series Alarm Parameter Manual 15 User Parameters 342 IB 1501279 H ...
Страница 360: ...16 343 IB 1501279 H Machine Parameters ...
Страница 748: ......