M800/M80/E80/C80 Series Alarm/Parameter Manual
1 Operation Errors (M)
6
IB-1501279-H
Details
The stored stroke limit I, II, IIB or IB function has activated.
Remedy
Move the machine manually.
Correct any setting error of the parameters for the stored stroke limit.
Details
The chuck/tail-stock barrier function turned ON, and an axis entered the stroke end state.
Remedy
Reset the alarm with reset, and move the machine in the reverse direction.
Details
2nd reference position return was performed before 1st reference position return has been completed.
Remedy
Execute 1st reference position return.
Details
The operation mode was changed to MDI during single block stop at the middle point of G28/G29/G30.
Remedy
Change the operation mode.
Reset to clear the alarm.
Details
The sensor signal was already ON when the tool measurement mode (TLM) signal was validated.
The sensor signal turned ON when there was no axis movement after the tool measurement mode (TLM) signal
was validated.
The sensor signal turned ON at a position within 100
μ
m from the final entry start position.
Remedy
Turn the tool measurement mode signal input OFF, and move the axis in a safe direction.
Disabling the sensor signal also clears the operation alarm.
(Note) When the "tool length measurement 1" signal is disabled, the axis can be moved in either direction. Pay
attention to the movement direction.
Details
Reference position retract was performed while the coordinates had not been established.
Remedy
Execute reference position return.
Details
Reference position return had been performed during the tool retract and return, which invalidated the tool com-
pensation amount after the reference position return.
Remedy
The error is cleared if the operation mode is changed to other than reference position return before the
axis performs reference position return.
The error is cleared when the tool return is completed.
The error is cleared if reset 1 is input or the emergency stop button is pushed.
M01
S/W stroke end axis exists
0007
M01
Chuck/tailstock stroke end ax
0008
M01
Ref point return No. invalid
0009
M01
Illegal op in mid pt sg block
0013
M01
Sensor signal illegal ON
0019
M01
Ref point retract invalid
0020
M01
Tool ofs invld after R-pnt
0021
Содержание C80 Series
Страница 1: ......
Страница 7: ......
Страница 11: ......
Страница 13: ......
Страница 15: ......
Страница 18: ...1 IB 1501279 H Alarm ...
Страница 19: ...M800 M80 E80 C80 Series Alarm Parameter Manual 2 IB 1501279 H ...
Страница 20: ...1 3 IB 1501279 H Operation Errors M ...
Страница 54: ...2 37 IB 1501279 H Stop Codes T ...
Страница 62: ...3 45 IB 1501279 H Servo Spindle Alarms S ...
Страница 81: ...M800 M80 E80 C80 Series Alarm Parameter Manual 3 Servo Spindle Alarms S 64 IB 1501279 H ...
Страница 82: ...4 65 IB 1501279 H MCP Alarms Y ...
Страница 98: ...5 81 IB 1501279 H System Alarms Z ...
Страница 111: ...M800 M80 E80 C80 Series Alarm Parameter Manual 5 System Alarms Z 94 IB 1501279 H ...
Страница 112: ...6 95 IB 1501279 H Absolute Position Detection System Alarms Z7 ...
Страница 117: ...M800 M80 E80 C80 Series Alarm Parameter Manual 6 Absolute Position Detection System Alarms Z7 100 IB 1501279 H ...
Страница 118: ...7 101 IB 1501279 H Distance coded Reference Scale Errors Z8 ...
Страница 120: ...8 103 IB 1501279 H Emergency Stop Alarms EMG ...
Страница 124: ...9 107 IB 1501279 H Computer Link Errors L ...
Страница 126: ...10 109 IB 1501279 H User PLC Alarms U ...
Страница 136: ...11 119 IB 1501279 H Network Service Errors N ...
Страница 139: ...M800 M80 E80 C80 Series Alarm Parameter Manual 11 Network Service Errors N 122 IB 1501279 H ...
Страница 140: ...12 123 IB 1501279 H Program Errors P ...
Страница 178: ...13 161 IB 1501279 H Smart Safety Observation Alarm V ...
Страница 192: ...14 175 IB 1501279 H Multi CPU Errors A C80 ...
Страница 215: ...M800 M80 E80 C80 Series Alarm Parameter Manual 14 Multi CPU Errors A C80 198 IB 1501279 H ...
Страница 216: ...199 IB 1501279 H Parameter ...
Страница 217: ...M800 M80 E80 C80 Series Alarm Parameter Manual 200 IB 1501279 H ...
Страница 218: ...15 201 IB 1501279 H User Parameters ...
Страница 359: ...M800 M80 E80 C80 Series Alarm Parameter Manual 15 User Parameters 342 IB 1501279 H ...
Страница 360: ...16 343 IB 1501279 H Machine Parameters ...
Страница 748: ......